Installation

Wet Clean Processing

For wet clean processing, program the standard test cycle to verify proper operation of the wet clean system. (Refer to the Cabinet Freestanding Operation/Programming manual.)

Run the test cycle and verify that the wet clean system is operating properly:

Check plumbing connections for leaks.

Verify that the Premium Wet Clean Module pump is operating properly, and that the rotation direction is counterclockwise. If rotation direction is incorrect, a qualified electrician may reverse any two leads. See Step 6i of Premium Wet Clean Module installation section.

Verify that the drain valve on the Premium Wet Clean Module opens and closes properly.

Verify that the canister lid does not leak.

If problems arise during the control function test, stop the washer-extractor and return to the Premium Wet Clean Module installation section for proper installation of components and wiring.

44

F232058