Installation

Control Function Test

The washer-extractor should be cleaned after the installation is complete. A function test should then be executed on the unloaded machine:

1.Verify that power supply voltage and phase are correct in accordance with the washer-extractor’s requirements. If the Premium Wet Clean Module is installed, 3-phase power must be provided.

2.Open manual shut-off valves to the washer-extractor.

3.Press the Emergency Stop button.

4.Apply power to the washer-extractor.

5.Release the Emergency Stop button.

6.Check the door interlock before starting operation:

a.Attempt to start the washer with the door open. The washer-extractor should not start with the door open.

b.Close the door without locking it and attempt to start the washer. The washer should not start with the door unlocked.

c.Close and lock the door and start a cycle. Attempt to open the door while the cycle is in progress. The door should not open.

If the door lock and interlock are not functioning properly, call a service technician.

7.For standard processing, select Cycle 01 by pressing key 0 and key 1 on the keypad. Then press the Start key.

Run a complete cycle, checking operation of water inlet valves, drain, and extract functions.

42

F232058