Adapter
Plate
Upper
Recirculation
Pipe
Lower
Recirculation
Pipe
Filter
Pump
R0041
R004I
Figure 26
d.Tighten the clamps on the hose connector at the shell recirculation adapter plate. Ensure that the upper recirculation pipe is tight and fully secured.
e.Align the lower recirculation pipe to the upper recirculation pipe and the pump outlet. Ensure that the water recirculation platform can be positioned so that the flex hose from the left drain to the canister/filer bends comfortably.
If the flex hose appears to be crimped or stretched excessively, flip the lower recirculation pipe around and reposition the water recirculation platform until the flex hose bends comfortably.
Installation
f.Slide one 1
g.Assemble the other 1
h.Position the lower recirculation pipe between the upper recirculation pipe and the pump outlet. Verify alignment. Secure the lower recirculation pipe to the pump outlet by tightening the clamps on the 1
i.Slide the other 1
j.Verify that all pipe connections are tight and fully secure.
Verify operation with Control Function test, which follows this section in the manual.
41
F232058