Adapter

Plate

Upper

Recirculation

Pipe

Lower

Recirculation

Pipe

Filter

Pump

R0041

R004I

Figure 26

d.Tighten the clamps on the hose connector at the shell recirculation adapter plate. Ensure that the upper recirculation pipe is tight and fully secured.

e.Align the lower recirculation pipe to the upper recirculation pipe and the pump outlet. Ensure that the water recirculation platform can be positioned so that the flex hose from the left drain to the canister/filer bends comfortably.

If the flex hose appears to be crimped or stretched excessively, flip the lower recirculation pipe around and reposition the water recirculation platform until the flex hose bends comfortably.

Installation

f.Slide one 1 1/2-inch black connector (with clamp grooves), included in the kit, onto the upper recirculation pipe side of the lower recirculation pipe.

g.Assemble the other 1 1/2-inch black connector (with clamp grooves), included in the kit, to the pump outlet.

h.Position the lower recirculation pipe between the upper recirculation pipe and the pump outlet. Verify alignment. Secure the lower recirculation pipe to the pump outlet by tightening the clamps on the 1 1/2-inch black connector.

i.Slide the other 1 1/2-inch connector between the upper and lower recirculation pipes. Tighten the connector clamps.

j.Verify that all pipe connections are tight and fully secure.

Verify operation with Control Function test, which follows this section in the manual.

41

F232058