Entering Program Mode

1.Unlock and raise top cover.

2.Remove control module cover.

3.Locate the Run/Program Mode switch near center of computer board inside control module. Refer to Figure 1.

1

2

B152R

1Run/Program Mode Switch

2Computer Board

Figure 1

4.Flip switch to down position to enter Program Mode. Display will show current temperature of sump.

Programming Setup Mode

NOTE: Selection of degrees Fahrenheit or Celsius is only option for setup.

1.Press Stop (*) key to enter Setup Mode while display is showing temperature in sump.

2.Use Up or Down (arrow) key to change selected option. Press Start (#) key to accept selected option, either “FAr” or “CEL”.

3.Press Stop (*) key to exit Setup Mode.

Programming

Programming a Cycle

1.Press Up (arrow) key until computer display shows segment to be edited. Press Start (#) key.

2.Use Up or Down (arrow) key to select desired segment time. Refer to Table 2. Set value to zero to skip segment. Press Start (#) key.

Time and Temperature Parameters

Segment

Minimum

Maximum

 

 

 

PreWash

1 minute

30 minutes

 

 

 

Wash

2 minutes

20 minutes

 

 

 

Fill 1

2 minutes

15 minutes

 

 

 

Fill 2

2 minutes

15 minutes

 

 

 

Fill 3

2 minutes

15 minutes

 

 

 

Fill 4

2 minutes

15 minutes

 

 

 

Fill 5

2 minutes

15 minutes

 

 

 

Fill 6

2 minutes

15 minutes

 

 

 

Intermediate Spin

30 seconds

120 seconds

 

 

 

Final Spin

1 minute

10 minutes

 

 

 

Temperature

75°F (25°C)

200°F (93°C)

 

 

 

 

Table 2

 

NOTE: Spin times in cycle segments 1 – 8 are entered in seconds (30 to 120), and time for final spin in segment 11 is entered in minutes (1 to 10).

NOTE: The computer does not count down the remaining cycle time during fills, drains, or prior to first achieving the programmed heat temperature when heating. The computer resumes counting down cycle time once the programmed fill level is reached, when the machine has drained, and after a programmed heat temperature is reached.

WARNING

To avoid personal injury, recommended inlet water temperature should be no higher than 125° Fahrenheit (51° Celsius).

W709

F232139

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9