SPECIFICATIONS
STEAM HEATED DRYERS | Operating Steam Pressure | ........................ | 100 PSIG | (6.9 bar) Max. |
|
| ||||
ONLY | Boiler HP (w/normal ld.) (14FPI) ........... | 10.4 (7.76 kW) |
|
|
| |||||
|
|
|
| |||||||
| 7.87 (5.88 kW) |
|
|
| ||||||
| 9.5 (5.88 kW) |
|
|
| ||||||
| Steam Coils ............................................... | (2) | ||||||||
|
|
|
|
| (2) (1029 mm x 401 mm x 153 mm) | |||||
| Traps for Steam Heating Coils ................. | 3/4” (20 mm) (DN20) (2) |
|
| ||||||
| Steam Supply Line .................................... | 3/4” (20 mm) (DN20) |
|
|
| |||||
| Steam Return Line .................................... | 3/4” (20 mm) (DN20) |
|
|
| |||||
ELECTRIC LAUNDRY |
|
|
|
|
|
|
|
|
|
|
Drying Time |
|
|
|
|
|
|
| |||
DRYER (see Electric Bonnet | (Dry Weight)..................................................... | 110 lb. (49.9 kg) Indian Head cloth | ||||||||
Sheet) |
| 80 kW |
| |||||||
| (Approx. - teasting in lab.)..................................................... | 70% water retention - 31 min. | ||||||||
|
| 80 kW |
| |||||||
|
|
|
|
| 50% water retention - 23 min. | |||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Minimum Size |
|
| |
|
|
|
| Heater Amps, |
|
| Supply Wire |
| Branch | |
|
|
|
| Motor Amps, |
|
| Based on 75° | C | ||
|
|
|
|
|
| Circuit | ||||
|
| Rated Heater Input |
| Control Amps, | HZ. |
| (167 F) |
| ||
|
|
|
|
| Maximum | |||||
|
|
|
| Total Amperes |
|
| Insulated |
| ||
|
|
|
|
|
|
| Fuse Size. | |||
|
|
| at Rated Voltage |
|
| Copper |
| |||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| Conductor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60kW @ 208V/3Ph. |
| 174 Amps | 60 |
| 000 MCM |
| 200 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60kW @ 240V/3Ph. |
| 152 Amps | 60 |
| 00 MCM |
| 175 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60kW @ |
| 89 Amps | 50 |
| 2 AWG |
| 110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60kW @ 480V/3Ph. |
| 77 Amps | 60 |
| 3 AWG |
| 90 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 60kW @ 575V/3Ph. |
| 63 Amps | 60 |
| 4 AWG |
| 80 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Page 13