Operation

 

 

 

 

 

Display Indications

 

Display

Meaning

Display

Meaning

FC 5

Program identification code (ROM). This

 

HFIL

Hot fill

is an example only.

Lo

Low water level

 

 

 

 

 

Hold

Wait...power has just been turned on.

ned

Medium water level

 

 

 

 

PAY/(price)*

Pay (flashes alternately with start price if

 

HI

High water level

“FLSH” SETUP option is enabled)

SUP0

No supplies

 

 

 

 

 

CY

Cycle (followed by two-digit number)

SUP1

Supply 1

 

 

 

 

tESt/CYC*

Test cycle selected.

SUP2

Supply 2

 

 

 

 

FAr

Degrees Fahrenheit

SUP3

Supply 3

 

 

 

 

CEL

Degrees Celsius

SUP5

Supply 5 (Supply 1 and 2)

 

 

 

 

Heat

Auxiliary heat enabled.

SUP6

Supply 6 (Supply 2 and 3)

 

 

 

 

noHt

Auxiliary heat disabled.

drAI/dISt*

Distribution (load balancing before extract)

 

 

 

 

 

FLSH

Flashing vend price enabled.

drAI/For*

Drain step (low speed forward in test

cycle)

 

 

 

 

 

 

 

 

nFLS

Flashing vend price disabled.

SPIn/tInE*

Reads “SPIn” for one second, then

 

 

 

“tI nE” followed by time for spin.

Strt/Ant*

Start amount—flashes briefly before

 

 

showing vend price in SETUP mode

SdLY

Spin coast delay

 

 

 

 

 

Con1/deno*

Coin 1 value—flashes briefly before

 

STOP

Stop routine

showing value of coin 1 in SETUP mode

donE

Cycle and stop routine have ended.

 

 

 

 

 

Con2/deno*

Coin 2 value—flashes briefly before

 

HI 1

Low spin in test cycle.

showing value of coin 2 in SETUP mode

HI 2

High spin in test cycle.

 

 

 

 

 

PrE

Prewash segment (1st of 8 segments)

bAL/FAIL*

Balance routine failed during test cycle.

 

 

 

 

UASH

Wash segment (2nd of 8 segments)

SHUT/door*

Door not properly closed.

 

 

 

 

FIL1

First fill (3rd of 8 segments)

CANt/OPEN*

Computer cannot unlock door after five

FIL2

Second fill (4th of 8 segments)

attempts.

 

 

 

 

 

FIL3

Third fill (5th of 8 segments)

FILL/STOP*

Programmed water level not reached after

FIL4

Fourth fill (6th of 8 segments)

30 minutes.

 

 

 

 

 

FIL5

Fifth fill (7th of 8 segments)

FULL

The computer detects low water level or

FIL6

Sixth fill (8th of 8 segments)

higher when none should be present.

 

 

 

 

 

AFIL

Auxiliary fill

dFLt

Drive fault detected.

 

 

 

 

bFIL

Warm fill (both hot and cold)

 

Temperature sensor failure or temperature

 

 

 

 

CFIL

Cold fill

tSFL

out of range.

 

 

 

 

bLCH

Add bleach

 

 

 

*Display indications separated by a slash represent an alternating display.

15