Operation
Display Indications
Display | Meaning | Display | Meaning | |
FP1 | Program identification code (ROM). This is an | Med | Medium water level | |
| example only. |
|
| |
|
|
|
| |
Hold | Wait...power has just been turned on. | HI | High water level | |
|
|
|
| |
CY | Cycle (followed by | SUP1 | Supply 1 | |
|
|
|
| |
tESt/CYC* | Test cycle selected. | SUP2 | Supply 2 | |
|
|
|
| |
FAr | Degrees Fahrenheit | SUP3 | Supply 3 | |
|
|
|
| |
CEL | Degrees Celsius | SUP4 | Supply 4 | |
|
|
|
| |
Heat | Auxiliary heat enabled. | SUP5 | Supply 5 (SETUP option) | |
|
|
|
| |
noHt | Auxiliary heat disabled. | SUP6 | Supply 6 (supply 1 and 5) | |
|
|
|
| |
tFIL | SUP7 | Supply 7 (supply 3 and 4) | ||
|
|
|
| |
ntFL | SLo/For | Gentle wash speed, forward direction | ||
|
|
|
| |
CooL | Automatic | SLo/rEv | Gentle wash speed, reverse direction | |
|
|
|
| |
noCL | Automatic | norM/For | Normal wash speed, forward direction | |
|
|
|
| |
Ag 1 | Agitation 1 selected (90% agitation). | norM/rEv | Normal wash speed, reverse direction | |
|
|
|
| |
Ag 2 | Agitation 2 selected (33% agitation). | drAI | Drain enabled. | |
|
|
|
| |
Ag 3 | Agitation 3 selected (10% agitation). | nodr | Drain disabled. | |
|
|
|
| |
Ag 4 | Agitation 4 selected (6.7% agitation). | dISt | Distribution (load balancing before extract) | |
|
|
|
| |
AgSn | Agitation speed normal | SPIn/tIME* | Reads “SPIn” for one second, then “tIME” | |
|
| followed by time for spin. | ||
AgSL | Agitation speed low | |||
| ||||
|
| |||
|
|
|
| |
PMP | Pump output enabled (future use only). | SPn1 | Lowest of three spins | |
|
|
|
| |
nPMP | Pump output disabled (future use only). | SPn2 | Middle of three spins | |
|
|
|
| |
PrE | Prewash segment (1st of 11 segments) | SPn3 | Highest of three spins | |
|
|
|
| |
UASH | Wash segment (2nd of 11 segments) | STOP | Stop routine | |
|
|
|
| |
FIL1 | First fill (3rd of 11 segments) | SdLY | Spin coast delay | |
|
|
|
| |
FIL2 | Second fill (4th of 11 segments) | donE | Cycle and stop routine have ended. | |
|
|
|
| |
FIL3 | Third fill (5th of 11 segments) | dFLt | Drive fault detected. | |
|
|
|
| |
FIL4 | Fourth fill (6th of 11 segments) | door | Door not properly closed. | |
|
|
|
| |
FIL5 | Fifth fill (7th of 11 segments) | bAL/FAIL* | Balancing routine failed during test cycle after | |
|
| 10 attempts to balance load. | ||
FIL6 | Sixth fill (8th of 11 segments) | |||
| ||||
|
| |||
|
|
|
| |
FIL7 | Seventh fill (9th of 11 segments) | FILL/STOP* | Programmed water level not reached after 30 | |
FIL8 | Eighth fill (10th of 11 segments) | minutes. | ||
| ||||
|
|
|
| |
FIL9 | Ninth fill (11 of 11 segments) | FULL | The computer detects low water level or higher | |
|
| when none should be present. | ||
CFIL | Cold fill | |||
| ||||
|
| |||
|
|
|
| |
bFIL | Warm fill (both hot and cold) | rotA | Computer detects possible rotation of motor | |
|
| when there should be none. | ||
HFIL | Hot fill | |||
| ||||
|
| |||
|
|
|
| |
AFIL | Auxiliary fill (SETUP option) | tSFL | Temperature sensor failure or temperature out of | |
|
| range. | ||
Lo | Low water level | |||
| ||||
|
|
*Display indications separated by a slash represent a flashing display.
16 | F232072 |