y.All outputs are turned off for roughly 20 seconds. The display shows “SdLY” (spin coast delay).
z.The computer performs the normal stop routine.
Programming
Supply Dispenser
Compartments
1 2 3
The door interlock is energized (allowing the door to be opened), provided that the water level switch indicates that water has fallen
1 2 3
4
below low level and that the AC drive indicates that the motor has stopped.
Chemical Injection Supply System
The external supply connections are located on the rear of the machine. The supply dispenser compartments are designated 1, 2, and 3, in that order, viewed from the front of the machine, left to right.
The external supply hoses empty into the supply dispenser compartments as follows: external supply 1 empties into compartment 1, external supply 2 empties into compartment 2, and external supplies 3 and 4 empty into compartment 3. See Figure 4.
Chemical Supply
Injection Points
B009RE3B
Figure 4
Compartment 1 flushes with each fill. Compartment 2 flushes when the program calls for supply 2 during a fill. Compartment 3 flushes when the program calls for supply 3 during a fill.
Note: Compartment 3 does not flush when supply 4 is called for in a program.