Installation
3.Remove ground screw and save for use in Step 5. Remove wire and use in Step 6.
1
5.Attach power cord ground (green) wire to rear bulkhead using ground screw removed in Step 3.
1
7
6
5
D697I
D697I
1Ground Screw
4
2
Figure 19
4.Use a strain relief and insert end of power cord through power supply hole.
D696I
Figure 20
DRY1920N
3
DRY1920N
1White
2“L2” Terminal
3Black
4Green
5Red
6Neutral Terminal
7“L1” Terminal
Figure 21
6.Use the three screws from the accessories bag to attach the remaining power cord wires to the terminal block as follows:
a.Red wire to “L1” terminal.
b.Black wire to “L2” terminal.
c.White wire to Neutral terminal.
NOTE: When installing the white wire, loop the free eyelet end of the ground wire (removed in Step 3) and attach along with the white wire to the neutral (center) terminal on the terminal block.
7. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block.
8.Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet.
9.Check the continuity of the ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet.
10.Reinstall access cover and screw.
22 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 510977 |