Operation

Table 2 lists the various displays and what they mean. The operator should become familiar with these computer displays.

Display Indications

Display

Meaning

Display

Meaning

 

 

 

 

vv01

Program identification code (ROM)

SPC?

Special test cycle function (if present, ignore)

Example only.

 

 

Lo

Low water level

 

 

 

 

 

 

Hold

Wait...power has just been turned on.

nEd

Medium water level

CY

Cycle (followed by two-digit number)

HI

High water level

 

 

 

 

tESt/CYC*

Test cycle selected.

SUP1

Supply 1

 

 

 

 

FAr

Degrees Fahrenheit

SUP2

Supply 2

 

 

 

 

CEL

Degrees Celsius

SUP3

Supply 3

 

 

 

 

HEAt

Auxiliary heat enabled.

SUP4

Supply 4

 

 

 

 

noHt

Auxiliary heat disabled.

SUP5

Supply 5 (SETUP option)

 

 

 

 

tFIL

Temperature-controlled fill enabled.

SUP6

Supply 6 (supply 1 and 5)

 

 

 

 

ntFL

Temperature-controlled fill disabled.

SUP7

Supply 7 (supply 3 and 4)

 

 

 

 

CooL

Automatic cool-down enabled.

SLo/For**

Gentle wash speed, forward direction

 

 

 

 

noCL

Automatic cool-down disabled.

SLo/rEv**

Gentle wash speed, reverse direction

 

 

 

 

Ag 1

Agitation 1 selected (90% agitation).

norn/For

Normal wash speed, forward direction

Ag 2

Agitation 2 selected (33% agitation).

norn/rEv

Normal wash speed, reverse direction

Ag 3

Agitation 3 selected (10% agitation).

drAI

Drain enabled.

 

 

 

 

Ag 4

Agitation 4 selected (6.7% agitation).

nodr

Drain disabled.

 

 

 

 

AgSn

Agitation speed normal

dISt

Distribution (load balancing before extract)

 

 

 

 

AgSL**

Agitation speed low

SPIn/tInE*

Reads “SPIn” for one second, then “tInE” followed by

 

 

time for spin.

PUnP

Pump output enabled (future use only).

 

 

nPnP

Pump output disabled (future use only).

SPn1

Lowest of three spins

PrE

PreWash segment (1st of 11 segments)

SPn2

Middle of three spins

 

 

 

 

UASH

Wash segment (2nd of 11 segments)

SPn3

Highest of three spins

 

 

 

 

FIL1

First fill (3rd of 11 segments)

STOP

Stop routine

 

 

 

 

FIL2

Second fill (4th of 11 segments)

SdLY

Spin coast delay

 

 

 

 

FIL3

Third fill (5th of 11 segments)

donE

Cycle and stop routine have ended.

 

 

 

 

FIL4

Fourth fill (6th of 11 segments)

dFLt

Drive fault detected.

 

 

 

 

FIL5

Fifth fill (7th of 11 segments)

door

Door not properly closed.

 

 

 

 

FIL6

Sixth fill (8th of 11 segments)

BAL/door*

Indicates vibration switch or door locked switch tripped

 

 

during spin.

FIL7

Seventh fill (9th of 11 segments)

 

 

 

 

 

 

FIL8

Eighth fill (10th of 11 segments)

FILL/STOP*

Programmed water level not reached after

 

 

30 minutes.

FIL9

Ninth fill (11th of 11 segments)

 

 

 

 

 

 

CFIL

Cold fill

FULL

The computer detects low water level or higher when

 

 

none should be present.

bFIL

Warm fill (both hot and cold)

 

 

 

 

 

 

HFIL

Hot fill

tSFL

Temperature sensor failure or temperature out of range.

 

 

 

 

AFIL

Auxiliary fill (SETUP option)

bAL?

Special test cycle function (if present, ignore)

 

 

 

 

* Display indications separated by a slash represent a flashing display.

** The washer-extractor will operate at normal wash speed regardless of the speed settings.

Table 2

12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232183