Chapter 1: Overview
22
Figure 6. Removable and Non-removable Power Supply Modules in x610
Switches
To summarize, a non-PoE+ x610 Series switch uses the AT-RPS3000
Chassis as its active source of system power and its internal, non-
removable module as a redundant source. For a PoE+ x610 Series switch
the reverse is true because its primary source of system power is its
removable internal module and the redundant source is the power module
in the AT-RPS3000 Chassis.
System power for PoE+ and non-PoE+ x610 Series switches is provided
by all four RPS ports on the AT-RPS3000 Chassis. RPS 1 and 3 System
ports provide only system power, and RPS 2 and 4 PoE+/System ports
provide PoE+ power in addition to system power.
You may use any of the available power supply modules, listed in Table1
on page 19, to provide system power to the x610 Series switches. In fact,
the modules, when installed in the AT-RPS3000 Chassis, can provide
system power to two low-power switches at the same time, as explained in
“Low-power and High-power Switches” on page 24.
The switch and chassis do not display the active or redundant status of a
power supply module. You may use the LEDs and switch’s management
software to determine whether a power module is operating correctly, but
not whether it is the active or redundant system power for the switch.
PoE+ Power The four x610 Series switches that support PoE+ on the twisted pair ports
do not come with power supply modules. The modules have to be
purchased separately. You may use any of the three modules in a PoE+
switch, although the AC AT-PWR250 Module does not provide PoE+
power, only system power. The AT-PWR800 and AT-PWR1200 Power
Supply Modules provide 480 and 780 watts, respectively, of PoE+ power,
in addition to system power.
As explained earlier in this Overview, there is no load sharing of system
power between the power supplies in the switch and AT-RPS3000
Chassis. Only one source is active while the other is held in a redundant
state.
POWER SUPPLY
WARNING
This unit m
electric sho
unit.
AT-PWR800
100-240 VAC~5A MAX
POWER SUPPLY
WARNING
This unit ma
electric shoc
unit.
2158
DC OUT
FAULT
100-240 VAC~12A MAX
Non-removable Power SupplyRemovable Power Supply
(PoE+ Switches) (non-PoE+ Switches)