4Patch Release Note

PCR: 02423

Module: SWI

Network affecting: No

IGMP messages sometimes caused a fatal error. This issue has been

resolved.

 

 

PCR: 02425

Module: IPG

Network affecting: No

Multicast downstream groups are now added and deleted correctly.

Errata

AT-9800 Series Switches do not have Ethernet interfaces (for example, eth0). Previously released documentation incorrectly states that these interface types are valid. AT-9800 switch ports are Ethernet ports, and these are referenced in commands with the PORT parameter.

IPSec and ISAKMP are not available on the 2.4.4 release for SwitchBlade 4000

Series Switches and AT-9800 Series Switches.

Availability

Patches can be downloaded from the Software Updates area of the Allied Telesyn web site at www.alliedtelesyn.co.nz/support/updates/patches.html. A licence or password is not required to use a patch.

Patch SB244-01 for Software Release 2.4.4 C613-10349-00 REV A

Page 4
Image 4
Allied Telesis SB244-01 manual Errata, Availability