Link Quality

Receiving AP link quality on infrastructure networking mode

 

 

Signal Strength

Receiving AP signal strength on infrastructure networking mode

 

 

5.REGULATION COMPLIANCE

Compliant with

FCC Part 15 Class B and C

ETSI EN 300 328-2 and ETSI EN 301 489-1, -17, EN60950, CE-Mark

Telec (Japan, Customized)

WiFi Compliant

6.Environmental Requirement

6.1. Drop and Vibration

6.1.1. Anti-Static Voltage

Static voltage tests by 4 kV in card frame should not cause system fail

6.1.2. Vibration Test

The vibration test is under the frequency and amplitude 10-25 Hz 1mm in vertical and horizontal direction by 30 minutes that should not cause any damage on product.

6.1.3. Package Drop Test

Dropping the package from the height of 50cm for each of the six(6) faces onto the hard-wood floor should not cause any damage on product.

6.2. Operation Environment

6.2.1. Temperature Range

Operating:

-0- +55(Except RF output power and sensitivity)

Storage:

-20- +70

6.2.2. Reliability Test

One cycle of reliability test is keeping at -30by 2 hours, switching temperature up to +60within one hour , and testing at +60by 2 hours, and switching temperature to -30within one hour. Three cycle should be tested and without any product fail.

6.2.3. Humidity

Operating:

0% to 70%

5

Page 5
Image 5
Alloy Computer Products GL242201 Drop and Vibration Anti-Static Voltage, Vibration Test, Package Drop Test, Humidity