Alto-Shaam 3DN electrical, DIScONNEcT uNIT frOM pOwEr SOurcE bEfOrE cLEANINg Or SErVIcINg, DANgEr

Models: drawer warmers 1DN 500-2D 2DN 500-1D 3DN 500-3D

1 27
Download 27 pages 33.78 Kb
Page 8
Image 8
electrical

i n s t a l l a t i o n

electrical

1.An identification tag is permanently mounted on the cabinet.

2.Plug cabinet into a properly grounded receptacle ONLY, positioning the unit so the power supply cord is easily accessible in case of an emergency.

Arcing will occur when connecting or disconnecting the unit unless all controls are in the “OFF” position.

3.If necessary, a proper receptacle or outlet configuration as required for this unit, must be installed by a licensed electrician in accordance with applicable, local electrical codes.

For CE approved units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization-bonding stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked DIScONNEcT uNIT frOM pOwEr SOurcE bEfOrE cLEANINg Or SErVIcINg.

with the following symbol.

hard wired models:

Hard wired models must be equipped with a country certified external allpole disconnection switch with sufficient contact separation.

If a power cord is used for the connection of the product an oil resistant cord like H05RN or H07RN or equivalent must be used.

NOTE: Where local codes and CE regulatory requirements apply, appliances must be connected to an electrical circuit that is protected by an external GFCI outlet.

c A u T I O N

THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICE TECHNICIANS ONLY AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.

Manual background DANgEr

DIScONNEcT uNIT frOM pOwEr SOurcE bEfOrE cLEANINg Or SErVIcINg.

DANgEr

To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/ NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.

ELECTRICAL

voltage phase cycle/hz amps kW

120

1

60

5.3

0.64

nema 5-15p

 

 

 

 

 

15A, 125V plug

208-240

1

60

2.7

0.64

nema 6-15p

15A, 250V plug

 

 

 

 

 

230

1

50/60

2.6

0.59

cee 7/7,

 

220-230V plug

Wire diagrams are located inside the bonnet of the unit.

MN-29742 • Rev. 1 (04/13) • Drawer Warmer Installation/Operation/Service Manual • 6

Page 8
Image 8
Alto-Shaam 3DN, 500-3D electrical, DIScONNEcT uNIT frOM pOwEr SOurcE bEfOrE cLEANINg Or SErVIcINg, c A u T I O N, DANgEr