i n s t a l l a t i o n
electrical
1.An identification tag is permanently mounted on the cabinet.
2.Plug cabinet into a properly grounded receptacle ONLY, positioning the unit so the power supply cord is easily accessible in case of an emergency.
Arcing will occur when connecting or disconnecting the unit unless all controls are in the “OFF” position.
3.If necessary, a proper receptacle or outlet configuration as required for this unit, must be installed by a licensed electrician in accordance with applicable, local electrical codes.
For CE approved units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an
with the following symbol.
hard wired models:
Hard wired models must be equipped with a country certified external allpole disconnection switch with sufficient contact separation.
If a power cord is used for the connection of the product an oil resistant cord like H05RN or H07RN or equivalent must be used.
NOTE: Where local codes and CE regulatory requirements apply, appliances must be connected to an electrical circuit that is protected by an external GFCI outlet.
c A u T I O N
THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICE TECHNICIANS ONLY AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.
DANgEr
DIScONNEcT uNIT frOM pOwEr SOurcE bEfOrE cLEANINg Or SErVIcINg.
DANgEr
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/ NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.
ELECTRICAL
voltage phase cycle/hz amps kW
120 | 1 | 60 | 5.3 | 0.64 | nema | |
|
|
|
|
| 15A, 125V plug | |
1 | 60 | 2.7 | 0.64 | nema | ||
15A, 250V plug | ||||||
|
|
|
|
| ||
230 | 1 | 50/60 | 2.6 | 0.59 | cee 7/7, | |
|
Wire diagrams are located inside the bonnet of the unit.