42

Wiring is subject

CONTROL BOX

 

LVJB

 

OUTDOOR POWER SUPPLY

 

 

 

 

 

 

 

 

SEE RATING PLATE

 

 

 

BL/PK

Y

 

NOTE 1

T1

 

 

 

T2

 

 

 

 

 

 

 

 

 

 

 

 

BL

C

 

 

 

2 1

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

SR

 

 

L2

 

 

C

SC

C

 

 

 

 

 

 

 

5

WIRING

to change. Always refer

SC

BL BK

 

 

 

 

 

 

 

LVJB

 

COLOR CODE

 

BK ---------------

 

BLACK

 

BL ---------------

BLUE

 

BL/PK ----------

BLUE/PINK STRIPE

 

BR ---------------

 

BROWN

 

OR ---------------

 

ORANGE

 

PU ---------------

 

PURPLE

 

RD ---------------

 

RED

 

WH --------------

 

WHITE

 

YL ---------------

YELLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTERNATE DOUBLE POLE CONTACTOR ONLY

CC

A D M

IO

CADM

H

C

 

A

U

X

S

 

 

RCCF

 

 

 

 

 

COMP

 

 

 

 

 

 

 

A

 

 

F

M

 

 

 

 

 

 

I

R

 

 

 

 

N

 

 

 

 

 

 

C

 

 

 

 

 

 

A

 

 

SA

 

 

 

D

 

 

 

 

 

 

 

(IF USED)

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

IO

 

 

 

 

 

 

 

A

U

X

 

 

 

 

 

 

 

 

 

 

 

CM

HIGH VOLTAGE! DISCONNECT UNIT. MULTIPLE DO SO MAY

DIAGRAMS

to the wiring diagram on the

BK

SR

5

 

1

2 BL

YL

T1 T2

 

 

BK

 

BK

RD

RD

BL

 

 

 

 

 

 

 

 

 

 

BL

T1

 

T2 RD

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

BL/PK

L1

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

PU

HERM

 

 

 

 

 

 

 

 

C

YL

YL

 

 

 

 

 

 

RD

F

 

 

 

 

 

 

 

 

 

 

 

 

 

BR

RCCF

YL

 

 

 

 

 

 

 

 

 

 

YL

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WIRING CODE

FACTORY WIRING

HIGH VOLTAGE

LOW VOLTAGE

OPTIONAL HIGH VOLTAGE

FIELD WIRING

 

CADM

HIGH VOLTAGE

 

Y

LOW VOLTAGE

 

C

 

M

A I N

C

ALL POWER BEFORE SERVICING POWER SOURCES MAY BE CAUSE PROPERTY DAMAGE,

ASX140[24 ASX140481CB /

unit for the most

L1 L2

ALTERNATE DOUBLE POLE CONTACTOR

BL RD YL

C Y R C S

CADM RD BK YL

BL/PK HPS BL/PK

SA (IF USED) NOTE 2

RD

NOTE 3

EQUIPMENT GROUND

COMPONENT CODE

C ---------------

CONTACTOR

CADM --------

COMFORT ALERT MODULE

CM ------------

OUTDOOR FAN MOTOR

COMP --------

COMPRESSOR

HPS -----------

HIGH PRESSURE SWITCH

IO --------------

INTERNAL OVERLOAD

LVJB ----------

LOW VOLTAGE JUNCTION BOX

HPS

C Y

OR INSTALLING PRESENT. FAILURE PERSONAL INJURY

-36]1CC ASX140601BC

up-to-date wiring.

MAIN

PU

AUX

BR

IO

BK

 

 

COMP

 

 

MAIN

RD

AUX

BK

YL

 

IO

 

 

C

S

 

 

R

 

 

RCCF ---------

RUN CAPACITOR FOR COMPRESSOR & FAN

SA -------------

START ASSIST

SC -------------

START CAPACITOR FOR COMPRESSOR (OPTIONAL)

SR -------------

START RELAY FOR COMPRESSOR (OPTIONAL)

CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.

NOTES:

1)TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT.

2)START ASSIST FACTORY EQUIPPED WHEN REQUIRED.

3)USE COPPER CONDUCTORS ONLY.

USE N.E.C.

CLASS 2 WIRE

THIS TO OR DEATH

.

CM

0140R00240-A

Page 42
Image 42
Amana ASX 14 SEER service manual ASX14024 ASX140481CB

ASX 14 SEER specifications

The Amana ASX 14 SEER is a high-efficiency air conditioning unit that stands out in today's market for its reliable performance and advanced technology. Engineered with a focus on cooling efficiency and cost-effectiveness, this system boasts a Seasonal Energy Efficiency Ratio (SEER) of 14, indicating its capability to provide substantial cooling while minimizing energy consumption. This makes it an ideal choice for homeowners looking to reduce their utility bills without compromising on comfort.

One of the standout features of the ASX 14 is its durable build quality. Constructed with galvanized steel, the cabinet is designed to withstand varying weather conditions, ensuring longevity and consistent performance. The durable finish not only adds to its resilience but also provides an attractive appearance that blends seamlessly with most home exteriors.

Another impressive characteristic of the ASX 14 SEER is its Quiet Comfort technology. This feature includes a sound-dampening system which significantly reduces operational noise, ensuring that your indoor environment remains peaceful and undisturbed. The advanced compressor design contributes to quieter operation, making this unit ideal for residential settings.

The ASX 14 is also equipped with a multi-speed blower motor. This technology allows for improved airflow and precise temperature control, enabling the system to adjust its cooling capacity based on the home’s specific needs. Additionally, the inverter technology used in this model enhances energy efficiency by reducing the power consumption during lower load conditions.

Moreover, the Amana ASX 14 SEER comes with a comprehensive warranty, highlighting the manufacturer’s confidence in the product. Many of these units are backed by a limited lifetime compressor warranty and a 10-year parts warranty, offering homeowners peace of mind regarding their investment.

Installation flexibility is another notable advantage of this model. It can be paired with various indoor units, allowing customers to configure a system that best suits their home’s layout and cooling requirements.

In summary, the Amana ASX 14 SEER is an exceptional choice for homeowners seeking a high-efficiency air conditioning unit. With its robust construction, energy-efficient technologies, quiet operation, and generous warranty, it delivers both comfort and reliability while setting a standard in the HVAC market.