RECESSED AREA OR CLOSET INSTALLATION
If a closet door is installed, the minimum ventilation openings in the top and bottom of the door are required (view 3). Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
Electrical:
15- or
| " |
|
" | " | " |
|
| " |
|
| " |
|
| " |
" | " | " |
"
"
12
3
DRAIN SYSTEM OPTIONS
Front view | Side view | Closet door with vents |
Standpipe drain system - wall or floor (view 1 & 2)
The standpipe drain requires a minimum diameter standpipe of 2 in. (5 cm). The minimum
The top of the standpipe must be at least 39 in. (99 cm) high and no higher than 96 in. (244 cm) from the bottom of the washer.
IMPORTANT: To avoid siphoning, no more than 8" (20.3 cm) of drain hose should be inside the standpipe.
Laundry tub drain system (view 3) The laundry tub needs a minimum
20 gal. (76 L) capacity. The top of the laundry tub must be at least 39 in.
(99 cm) above the floor and no higher than 96 in. (244 cm) from the bottom of the washer.
Floor drain system (view 4)
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of 28 in. (71 cm) from the bottom of the washer. Additional hoses might be needed.
39" (99 c m)
28"
39"(71 c m) (99 c m)
1 | 2 | 3 | 4 |
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10200331B |