PRODUCT MODEL NUMBERS
UXT5330AD UXT5336AD
Electrical: A 120 Volt, 60 Hz., AC only,
LOCATION REQUIREMENTS
●It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the left wall.
●Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.
30" (76.2 cm) or 36" (91.4 cm) min.
cabinet opening width
24" (61.0 cm) min. |
30" (76.2 cm) |
PRODUCT DIMENSIONS
| 1¹⁄₂" | |
12" | (3.8 cm) | |
1" | ||
(30.5 cm) 9" | ||
(2.5 cm) | ||
(22.9 cm) |
| |
| 2" | |
| (5.1 cm) |
9"
(22.9 cm)
³⁄₄" | 1¹⁄₂" | |
(1.9 cm) | ||
(3.8 cm) | ||
|
³⁄₈"
(9.5 mm)
7¹⁄₂"
(19.1 cm)
29⁷⁄₈" (75.9 cm) - 30" (76.2 cm) model | 20" |
35⁷⁄₈" (91.1 cm) - 36" (91.4 cm) model | (44.5 cm) |
|
VENTING REQUIREMENTS
Venting Methods
Vent system can terminate either through the roof or wall. Use 3¹⁄₄" x 10"
(8.3 x 25.4 cm) with a maximum vent length of 35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that gently reduce performance.
suggested max. |
|
bottom of cabinet |
|
to cooking surface | 13" (33.0 cm) |
| |
| cabinet depth |
18" (45.7 cm)
min. clearance upper cabinet to countertop
36" (91.4 cm) base cabinet height
Roof Venting
A | E |
B |
|
C |
|
D |
|
Wall Venting
A |
| |
B | E | |
C | ||
| ||
D |
|
A. 6" (15.2 cm) or larger round vent or a 3¹⁄₄" x 10" (8.3 x
25.4 cm) rectangular vent through roof
B.Round vent: use 6" (15.2 cm) or larger round damper (purchased separately)
C.Round vent: use 3¹⁄₄" x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece (purchased separately)
D.24" (61.0 cm) - 30" (76.2 cm) above cooking surface
E.Roof cap
A. 6" (15.2 cm) or larger round vent or a 3¹⁄₄" x 10" (8.3 x
25.4 cm) rectangular vent through the wall
B.Round vent: use 3¹⁄₄" x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece (purchased separately)
C.3¹⁄₄" x 10" (8.3 x 25.4 cm) through the wall
D.24" (61.0 cm) - 30" (76.2 cm) above cooking surface
E.Wall cap
|