Amana W10233410A manual Installation clearances, Dryer Dimensions, Closet installation Dryer only

Models: W10233410A

1 28
Download 28 pages 2.38 Kb
Page 5
Image 5

If you are using a power supply cord, a grounded electrical

outlet located within 2 ft (610 mm) of either side of the dryer.

See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 127 lbs

(57.6 kg). The combined weight of a companion appliance

should also be considered.

A level floor with a maximum slope of 1" (25 mm) under entire

dryer. (If slope is greater than 1" [25 mm], install Extended

Dryer Feet Kit, Part Number 279810.) Clothes may not tumble

properly and automatic sensor cycles may not operate

correctly if dryer is not level.

For a garage installation, you will need to place the dryer

at least 18" (460 mm) above the floor. If you are using a

pedestal, you will need 18" (460 mm) to the bottom of

Custom undercounter installation - Dryer only

 

 

2"*

 

 

(50 mm)

36" min

 

 

(914 mm)

 

 

1"*

27"

1"*

(25 mm)

(686 mm)

(25 mm)

*Required spacing

Closet installation - Dryer only

the dryer.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an auto cycle. Drying times can be extended.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Installation clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

 

14" max.*

48 in.2*

 

(356 mm)

 

 

 

(310 cm2)

 

18" min.*

 

 

(457 mm)

 

 

 

 

24 in.2*

 

 

 

(155 cm2)

1"*

28.65"

5"**

 

(25 mm) (728 mm)

(127 mm)

 

 

A

 

 

3"* (76 mm)

3"*

(76 mm)

B

50" (1283 mm)

36"

(914 mm)

*28.65"

 

(728 mm)

27"

(686 mm)

*Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

A. Side view - closet or confined area

B. Closet door with vents

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

Recessed or closet installation - Dryer on pedestal

 

 

 

 

14" max.

 

 

 

 

(356 mm)

 

 

 

 

18" min.*

 

 

 

 

(457 mm)

1"

27"

1"

1"*

28.65"

5"**

(25 mm)

(686 mm)

(25 mm)

(25 mm)

(728 mm)

(127 mm)

AB

A. Recessed area

B. Side view - closet or confined area

*Required spacing

**For side or bottom venting, 0" (0 mm) spacing is allowed.

5

Page 5
Image 5