WATER IS TOO HOT

1. Temperature Selection too high

Turn the temperature adjustment knob counter-clockwise (to the left) to lower the maximum water temperature. Note: This will increase the activation flow rate.

2.Inlet water temperature is very warm (60°-75°F) Reduce inlet gas supply to lower the heaters degree rise. Note: Only the Model 125BS should be used if the inlet water is preheated.

NOTE: Only the model 125B LPS or 125B NGS should be used if the inlet water is preheated.

3.Inlet filter screen is clogged, restricting flow Remove screen and clean it.

WATER IS NOT HOT ENOUGH

1. Temperature selection is set too low.

Change the setting. Turn the temperature selector knob clockwise (to the right). Note: this will decrease the activation flow rate.

2. Gas pressure is insufficient

It is extremely important for a tankless instantaneous water heater to have the right size gas line to obtain the correct gas pressure. See specifications on page 2. Unlike storage tank water heaters, the burners of a tankless water heater must be very powerful to heat water instantaneously since they do this only at the time hot water is actually being used. It is therefore imperative that the gas pressure requirement be met exactly. Insufficient gas pressure will directly affect the water temperature at the time of usage. See page 3 for correct gas pressure settings and see page 11 for proper gas line sizing.

3. Gas supply is insufficient

Make sure your main gas line is fully opened. If using LP gas, be sure that the size of the propane tank is adequate to supply the required gas pressure. See gas pipe sizing chart on page 11.

4.Cold water is mixing with the hot water between the 425 EF and the outlet

Compare water temperature at outlet of the 425 EF (hold the 425 EF outlet pipe with your hand) and at the tap. If these two are very different, check for mixing valve or plumbing crossover (see “NO SPARK AT THE PILOT” paragraph 4). Where automatic “anti-scald” valves are required by code, lower the temperature setting on the 425 EF as much as possible and balance the pressure between cold and hot water after the 425 EF.

5.Parts in water valve are dirty or damaged, which will prevent the gas valve from being fully opened.

If the internal water valve parts are damaged from water quality or use, or there is evident corrosion where the water valve and gas valve connect, then immediate service is needed. See step 9 under the problem NO SPARK AT THE PILOT. White vinegar should be applied first to any corrosion before the loosening of screws.

HOT WATER TEMPERATURE FLUCTUATES / UNIT DEACTIVATED

1. Unbalanced pressure in waterlines

The added restriction caused by the 425 EF in the hot water system can result in uneven pressures between the cold and the hot. In such cases when mixing cold water at the tap, the lower hot water pressure may be overpowered by a much higher cold water pressure, which may cause the 425 EF burners to shut down (deactivate). Make sure faucet aerators or shower heads are free of minerals.

Do not add any flow restrictor to the shower head. Typically this deactivation symptom is a result of the hot water being too hot to use comfortably. Warm inlet water generally causes this. Lowering the control knob setting and/or reducing the inlet gas supply to the heater should correct this deactivation symptom.

2. Temperature balance valves

If the inlet water temperature to the water heater is very warm the heater can produce temperatures that may be found to be too hot. A temperature balance shower valve can automatically mix in cold water to reduce such hot water temperature, in the event of any temperature instability with the use of a temperature balance shower valve, refer to shower valve manufactures instructions for internal adjustment setting. Adjustments should be made to the hottest setting in the shower valve. Additionally the temperature control of the heater can be adjusted to produce a more comfortable hot water temperature.

See SETTING THE WATER TEMPERATURE section.

3.Cold water is mixing with the hot water between the

425EF and the outlet

See #4 under “NO SPARK AT THE PILOT”.

4.Inlet water pressure is erratic due to inadequate supply water pressure or saturated pressure tank on well system

Check the inlet water pressure. For installation on a private well system with the use of a pressure tank, the lowest pressure range setting recommended is 30-50 psi (2.07- 3.45 bar). Confirm that the pressure tank is not water logged.

5.Gas pressure is too low

See page 3 for correct specifications.

EXHAUST FAN DOES NOT OPERATE

1.Check the fuse (see fig 9)

2.Check all electrical connections

3.Check adjustment of microswitch (see Fig. 14)

FAN CIRCULATES WHEN HOT WATER IS SHUT OFF

1. Check adjustment of microswitch (see Fig. 14)

FAN OPERATES WITHOUT WATER FLOW

1.Unplug the heater and first check that all electrical and electronic connections in the heater are clean and tight.

2.Check adjustment of microswitch (see Fig. 14).

3.Control box may need to be replaced (see Fig 9). Check wire connections and test operation of control box (see Fig 9).

6 720 607 017

19

Page 19
Image 19
American Dryer Corp GWH 425 EF manual FAN Circulates When HOT Water is Shut OFF

GWH 425 EF specifications

American Dryer Corp GWH 425 EF is a highly efficient, energy-saving dryer designed specifically for commercial laundry applications. With its robust construction and innovative technologies, the GWH 425 EF delivers exceptional performance while maximizing operational efficiency.

One of the main features of the GWH 425 EF is its optimized drying capacity. With a 45-pound load capacity, this dryer efficiently processes large volumes of laundry, making it an ideal choice for laundromats, hotels, and other commercial establishments. The dryer is designed to handle varied fabric types, providing versatile solutions for all drying needs.

The GWH 425 EF incorporates advanced heating technologies that enhance drying speed and efficiency. Its energy-efficient gas heating system not only reduces operation costs but also minimizes environmental impact. The dryer offers a range of adjustable temperature settings, enabling operators to customize drying cycles for different fabric types and load sizes. This flexibility enhances fabric care and improves overall drying performance.

Another standout characteristic of the GWH 425 EF is its user-friendly control panel. Equipped with a digital display, the control panel allows for easy programming and monitoring of drying cycles. Operators can select from multiple drying options, and the machine's intuitive interface makes it simple to adjust settings quickly. This convenience translates to improved workflow and increased productivity in busy commercial environments.

Safety is a top priority for American Dryer Corp, and the GWH 425 EF is equipped with multiple safety features. These include a built-in lint screen that traps lint and debris, reducing the risk of fires. Additionally, the dryer is engineered with a robust structural design, ensuring durability and longevity even under constant use.

The GWH 425 EF is also designed with maintenance in mind. It features easy access to internal components for routine servicing, allowing operators to keep the dryer in peak operating condition with minimal effort. This eases maintenance burdens and prolongs the lifespan of the machine.

Finally, the GWH 425 EF is backed by American Dryer Corp's commitment to quality and customer satisfaction. With a reputation for producing reliable and efficient laundry equipment, American Dryer Corp ensures that the GWH 425 EF meets the demanding needs of commercial laundry services. Overall, the American Dryer Corp GWH 425 EF is an excellent investment for businesses looking to optimize their laundry operations while maintaining quality and efficiency.