Heat Input/Gas Consumption/Orifice (Injector) Data
(For
Gas Specifications for Non-CE and Non-AGA Approved Dryers**
Model | Gas | Nominal | Supply | Gross | Orifice Size | Orifice | Burner | |||
Heating Value | Pressure | Heat Input |
|
| (Injector) | Pressure | ||||
| Type |
|
|
|
|
|
| Quantity |
| |
| Btu/ft3 | in WC | Btu/hr | kW | DMS | mm | in WC | |||
|
| |||||||||
M31SL | Natural | 1,000 | 55,000 | 16.12 | 20 | 4.089 | 1 | 3.0 | ||
*Liquid Propane | 2,500 | 11.0 | 55,000 | 16.12 | 44 | 2.184 | 1 | 10.0 | ||
| ||||||||||
M50SL | Natural | 1,000 | 90,000 | 26.38 | 29 | 3.454 | 2 | 3.0 | ||
*Liquid Propane | 2,500 | 11.0 | 90,000 | 26.38 | 47 | 2.994 | 2 | 10.0 | ||
| ||||||||||
M75SL | Natural | 1,000 | 110,000 | 32.24 | 22 | 3.988 | 2 | 3.0 | ||
*Liquid Propane | 2,500 | 11.0 | 110,000 | 32.24 | 44 | 2.184 | 2 | 10.0 | ||
|
Shaded areas are stated in metric equivalents
*Gas valve’s internal regulator disabled.
**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)
Gas Specifications for CE Approved Dryers**
| Gas |
|
| Nominal | Supply | Gross | Fuel | Orifice Size | Orifice | Burner | ||||
Model |
|
| Heating Value | Pressure | Heat Input | (Injector) | Pressure | |||||||
Type |
|
| Consumption |
|
| |||||||||
|
|
|
|
|
|
|
|
| Quantity |
| ||||
|
|
|
|
| Btu/ft3 | mb | Btu/hr | kW |
| DMS | mm | mb | ||
| Natural (I | /I |
| ) | 1,000 | 55,000 | 16.12 | 1.557 M3/H | 22 | 3.988 | 1 | 6.9 | ||
|
| 2H | 2E |
|
|
|
|
|
|
|
|
| ||
| Natural (I | ) |
|
| 830 | 55,000 | 16.12 | 1.876 M3/H | 22 | 3.988 | 1 | 9.5 | ||
|
| 2L |
|
|
|
|
|
|
|
|
|
|
| |
M31SL | Natural (I | 2 E LL | ) | 830 | 55,000 | 16.12 | 1.876 M3/H | 22 | 3.988 | 1 | 9.5 | |||
*Natural (I2E+) | 1,000 | 20 | 55,000 | 16.12 | 1.557 M3/H | 31 | 3.048 | 1 | — | |||||
| ||||||||||||||
| 830 | 25 | 55,000 | 16.12 | 1.876 M3/H | 31 | 3.048 | 1 | — | |||||
|
|
|
|
| ||||||||||
| *Butane (I3+) |
|
| 3,175 | 55,000 | 16.12 | 1.162 kg/H | 48 | 1.930 | 1 | — | |||
| *Propane (I3+) | 2,500 | 37 | 55,000 | 16.12 | 1.162 kg/H | 48 | 1.930 | 1 | — | ||||
| Butane (I3B/P) |
| 3,175 | 55,000 | 16.12 | 1.162 kg/H | 44 | 2.184 | 1 | 18.1 | ||||
| Propane (I3P) |
| 2,500 | 55,000 | 16.12 | 1.162 kg/H | 44 | 2.184 | 1 | 24.9 | ||||
| Natural (I | /I |
| ) | 1,000 | 90,000 | 26.38 | 2.549 M3/H | 29 | 3.454 | 2 | 7.2 | ||
|
| 2H | 2E |
|
|
|
|
|
|
|
|
| ||
| Natural (I | ) |
|
| 830 | 90,000 | 26.38 | 3.071 M3/H | 29 | 3.454 | 2 | 8.9 | ||
|
| 2L |
|
|
|
|
|
|
|
|
|
|
| |
M50SL | Natural (I2 E LL ) | 830 | 90,000 | 26.38 | 3.071 M3/H | 29 | 3.454 | 2 | 8.9 | |||||
*Natural (I2E+) | 1,000 | 20 | 90,000 | 26.38 | 2.549 M3/H | 35 | 2.794 | 2 | — | |||||
| ||||||||||||||
| 830 | 25 | 90,000 | 26.38 | 3.071 M3/H | 35 | 2.794 | 2 | — | |||||
|
|
|
|
| ||||||||||
| *Butane (I3+) |
|
| 3,175 | 90,000 | 26.38 | 1.901 kg/H | 50 | 1.778 | 2 | — | |||
| *Propane (I3+) | 2,500 | 37 | 90,000 | 26.38 | 1.901 kg/H | 50 | 1.778 | 2 | — | ||||
| Butane (I3B/P) |
| 3,175 | 90,000 | 26.38 | 1.901 kg/H | 47 | 1.994 | 2 | 18.1 | ||||
| Propane (I3P) |
| 2,500 | 90,000 | 26.38 | 1.901 kg/H | 47 | 1.994 | 2 | 24.9 | ||||
| Natural (I2H/I2E) | 1,000 | 110,000 | 32.24 | 3.115 M3/H | 22 | 3.988 | 2 | 6.9 | |||||
| Natural (I | ) |
|
| 830 | 110,000 | 32.24 | 3.753 M3/H | 22 | 3.988 | 2 | 9.5 | ||
|
| 2L |
|
|
|
|
|
|
|
|
|
|
| |
M75SL | Natural (I2 E LL ) | 830 | 110,000 | 32.24 | 3.753 M3/H | 22 | 3.988 | 2 | 9.5 | |||||
*Natural (I2E+) | 1,000 | 20 | 110,000 | 32.24 | 3.115 M3/H | 31 | 3.048 | 2 | — | |||||
| ||||||||||||||
| 830 | 25 | 110,000 | 32.24 | 3.753 M3/H | 31 | 3.048 | 2 | — | |||||
|
|
|
|
| ||||||||||
| *Butane (I3+) |
|
| 3,175 | 110,000 | 32.24 | 2.324 kg/H | 48 | 1.930 | 2 | — | |||
| *Propane (I3+) | 2,500 | 37 | 110,000 | 32.24 | 2.324 kg/H | 48 | 1.930 | 2 | — | ||||
| Butane (I3B/P) |
| 3,175 | 110,000 | 32.24 | 2.324 kg/H | 44 | 2.184 | 2 | 18.1 | ||||
| Propane (I3P) |
| 2,500 | 110,000 | 32.24 | 2.324 kg/H | 44 | 2.184 | 2 | 24.9 |
Shaded areas are stated in metric equivalents
*Gas valve’s internal regulator disabled.
**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
113431 - 10 | www.amdry.com | 19 |