90 DAYS
1.Remove lint from around basket (tumbler), drive motors, and surrounding areas.
2.Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment.
3.Clean any lint accumulation in and around both the blower and drive motor casing openings.
NOTE: To prevent damage, avoid cleaning or touching ignitor and
EVERY 6 MONTHS
Inspect and remove lint accumulation in customer furnished exhaust duct work system and from dryers internal exhaust ducting.
NOTE: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN CREATEAPOTENTIAL FIRE HAZARD.
NOTE: DO NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTILATION AIR.
CHECK CUSTOMER FURNISHED BACK DRAFT DAMPERS IN THE EXHAUST DUCT WORK. INSPECT and REMOVE ANY LINT ACCUMULATION WHICH CAN CAUSE THE DAMPER TO BIND or STICK.
NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown of the heat circuit safety switches or thermostats.
NOTE: When cleaning the dryer cabinets, avoid using harsh abrasives. Aproduct intended for the cleaning of appliances is recommended.
36