NOTE: Lint accumulation on the sensor bracket can act as an insulator which will affect the accuracy of the automatic drying cycle.
X.At the completion of the "AUTO" drying/cooling cycle, the load is coming out over dried...
1.Percent of dryness (dryness level) of the cycle selected is too high.
2.Factor "A" and Factor "B" is not set correctly or Factor "B" has to be adjusted for adverse local conditions.
Y.At the completion of the "AUTO" drying/cooling cycle, the load is coming out still damp...
1.Percent of dryness (dryness level) of the cycle selected is too low.
2.Factor "A" and Factor "B" is not set correctly or Factor "B" has to be adjusted for adverse local conditions.
53