Computer Board

The T-K2 Will Not Initiate

First check the flow rate through the unit. If the flow is not .75 GPM or greater, the unit will not initiate. Check the filter and the flow sensor for any debris or damage.

Press the lower green button on the GFCI inside the unit. If the red light above it does not come on, then there is a problem with the electrical supply to the unit. If that light does come on, hit the green reset button above the light, and look for the green light on the circuit plate at the top left of the unit. If this light is not lit, there is a problem with the electrical connection between the GFCI and the circuit plate. Contact Takagi Industrial Company for Instructions.

Error Codes

All Takagi units are self diagnostic for errors. If there is a problem with the installation or the unit, it will give a signal, through a pair of flashing lights on the circuit plate, to communicate the source of the problem. If the unit has a TK-RE01 remote control installed, this will give also give a numerical error code. Consult the following chart

for the meaning of an error code:

TK-RE01

Computer Board

TK-RE01

Check Point

 

 

Burning (red) LED: Blinking

11

Igniter

12

Flame Detector

Power (green) LED: OFF

51

Main Gas Valve

 

72

Pre Post Check

Burning (red) LED: OFF

03

Wrong Gas, Dip Switch

14

Hi-Limit Switch

Power (green) LED: Blinking

70

Computer Board

 

71

Proportional Valve

Burning LED and Power LED:

61

Fan Motor

Blinking Alternately

21

Vent Pipe

Burning LED and Power LED:

31

Thermistor

Blink Simultaneously

65

Water Control Valve

For technical support contact Takagi toll free at (888) 882-5244, or check our

website at www.takagi-usa.com.