First check the flow rate through the unit. If the flow is not .75 GPM or greater, the unit will not initiate. Check the filter and the flow sensor for any debris or damage.
Press the lower green button on the GFCI inside the unit. If the red light above it does not come on, then there is a problem with the electrical supply to the unit. If that light does come on, hit the green reset button above the light, and look for the green light on the circuit plate at the top left of the unit. If this light is not lit, there is a problem with the electrical connection between the GFCI and the circuit plate. Contact Takagi Industrial Company for Instructions.
Error Codes
All Takagi units are self diagnostic for errors. If there is a problem with the installation or the unit, it will give a signal, through a pair of flashing lights on the circuit plate, to communicate the source of the problem. If the unit has a
for the meaning of an error code:
Computer Board | Check Point | |
|
| |
Burning (red) LED: Blinking | 11 | Igniter |
12 | Flame Detector | |
Power (green) LED: OFF | 51 | Main Gas Valve |
| 72 | Pre Post Check |
Burning (red) LED: OFF | 03 | Wrong Gas, Dip Switch |
14 | ||
Power (green) LED: Blinking | 70 | Computer Board |
| 71 | Proportional Valve |
Burning LED and Power LED: | 61 | Fan Motor |
Blinking Alternately | 21 | Vent Pipe |
Burning LED and Power LED: | 31 | Thermistor |
Blink Simultaneously | 65 | Water Control Valve |
For technical support contact Takagi toll free at (888)