Page 2 of 12 8200-0492-02, Rev. C

Set the dome
address.
The address range is from 001
to 255, except for Manchester,
which is 01 to 64.
Set switches. Example: For
address 107, set SW3 to 1,
SW2 to 0, and SW1 to 7.
SW3 SW2 SW1
IMPORTANT! Both the outdoor housing and dome
camera are shipped “terminated” for when they are
installed at the end of a data cable. Should the cable
continue to another dome, “unterminate” the housing.
See information attached.
Place the desiccant bag in the pocket
located inside the housing and adjacent
to the blower/heater assembly.
Connect dome camera by aligning
protrusion on dome with florescent
marks on the mounting base.
Turn clockwise to
lock.
Remove and
discard both
eyeball covers.
To avoid motor damage,
turn eyeball slowly to
expose second cover!
IMPORTANT! Power the dome (heater fans turn on)
and check it performs its homing routine. During this
routine, the camera lens moves up into the dome
housing, down to the floor, pans slowly, and moves
up to its home position. The controller can then be
used to call up and control the dome.
If OK, continue. If not, see “Troubleshooting” in
information attached.
IMPORTANT! If installing a SpeedDome Ultra 8
dome in a legacy outdoor housing, go to the Dome
Information screen and select I/O Configuration.
Then select “Outdoor”. This setting will ensure
proper operation of the heater/blower.
A
ttach lanyard to stud
on flange of housing.
Secure with thumbnut.
A
ttach bubble
assembly.
A
ttach bubble to housing.
Vandal-resistant version has
additional shield installed.
Once the bubble is attached to the housing,
surface A must meet surface B on all sides.
Ensure lanyard is not caught between flange and
trim ring gasket, or trim ring and sunshield.
Ensure all four
tamperproof
screws are tight.
Sunshield
Check for
bent flange.
Discard
housing if
found.
Check for
cracks in
bubble.
Discard
bubble if
found.
4
A

B

5 A

B

C

6

A

B C

7
IMPORTANT! If the
bubble is attached to
the dome for up to 30
minutes or more and
then detached, the bag
must be replaced
before the bubble is
attached again. An
extra bag is supplied. If
more are needed,
order kit 0352-0207-02.
x100 x10 x1