SPEEDDOME ULTRA OUTDOOR HOUSING 8200-0492-02, REV. C
INSTALLATION GUIDE - CONTINUATION 5 of 12
Preventing Condensation
Damage, missing parts, or procedures
that most often allow water to enter
the housing are as follows (refer to
figures opposite):
Missing O-ring on cover, or missing sleeve or
seal on end cap assembly
Missing Teflon tape around any housing pipe
threads
RTV or similar sealant covering an air path
Blower fans not turning
Loose tamperproof screws in bubble assembly
Bent flange on metal housing that
compromises the gasket seal between the
bubble and the housing
Plugged drain holes in the bubble trim ring
Cracked bubble
Tamperproof screws that are missing or
improperly tightened compromise the gasket
seal between the bubble and the housing
Ensure lanyard is not caught between: a)
flange and trim ring gasket, and b) trim ring
and sunshield
In high humidity environments, the desiccant
bag may need to be replaced occasionally.
Parts List for Authorized Users
The parts listed below and shown in the exploded
view can only be ordered by authorized users. To
become authorized, contact your sales
representative.
1. Housing Assy., 0404-0260-03
2. Blower/Heater Assy., 0304-2906-01
3. I/O Board Assy., 0312-2124-03
4. Bubble Assy. (Clear), 0400-1402-01
5. Bubble Assy. (Smoke), 0400-1402-02
6. Drive, Tamperproof, 1400-0149-01
7. Screws, Tamperproof, 0500-8034-01 (x4)
8. Desiccant Kit, 0352-0207-02
Exploded view
Foam seal
(inside pipe)
Sleeve (outside),
Seal (inside end
cap assembly)
O-ring (inside
cover)
Bent flange
Gasket seal
between
bubble and
metal housing
Blower fans
1
2
3
6
4, 5
Additional shield (not
shown) used for vandal-
resistant version.
7