MegaRAID Enterprise 1600 Card Layout

Quick Hardware Installation Guide

Step 5 - Set Jumpers

Make sure the jumper settings on the MegaRAID Enterprise 1600 card are correct. Jumper setting details can be found in the Enterprise 1600 Hardware Guide.

Step 6 - Set SCSI Termination

Each MegaRAID SCSI channel can be individually configured for termination enable mode by setting the J2, J3, J5 and J7 jumpers.

You must terminate the SCSI bus properly. Set termination at both ends of the SCSI cable. The SCSI bus is an electrical transmission line and must be terminated properly to minimize reflections and losses. Typical configuration is to set the Termination Enable jumpers to allow software to set termination automatically.

Note: The default jumper settings on the controller for both Termination and TermPWR normally do not need to be changed.

Step 7 - Set SCSI Terminator Power (TermPWR)

Important - All MegaRAID Enterprise 1600 SCSI channels need TermPWR to operate. If a channel is not being used, make sure the TermPWR jumper for that channel is set to supply TermPWR from the PCI bus. Jumpers J9, J10, J11, and J12 control TermPWR on the Enterprise 1600.

Step 8 - Connect the Battery Harness (Optional)

You can install a battery pack onto the Series 471 MegaRAID Enterprise 1600 160M RAID controller. Call Technical Support at 770-246-8645 for more information.

Step 11 - Set Target IDs

Set target identifiers (TIDs) on the SCSI devices. Each device in a specific SCSI channel must have a unique TID in that channel. Non-disk devices, such as CD-ROM or tape drives, should have unique SCSI IDs regardless of the channel to which they are connected.

Step 12 - Power Up

Replace the computer cover and reconnect the AC power cords. Turn power on to the host computer. Set up the power supplies so the SCSI devices are powered up at the same time as or before the host computer. If the computer is powered up before a SCSI device, the device might not be recognized.

During boot, the MegaRAID Enterprise 1600 BIOS message appears:

MegaRAID Enterprise 1600 Disk Array Adapter BIOS Version x.xx date Copyright (C) American Megatrends, Inc.

Firmware Initializing . . . [Scanning SCSI Device ...(etc)... ]

The firmware takes several seconds to initialize. During this time the adapter will scan each SCSI channel. When it is ready, the following lines will appear:

host Adapter-1 Firmware Version x.xx date DRAM Size 8 MB 0 Logical Drives found on the Host Adapter

0 Logical Drives handled by BIOS

Press <Ctrl><M> to run MegaRAID Enterprise 1600 BIOS Configuration Utility

The <Ctrl> <M> prompt times out after several seconds.

The MegaRAID Enterprise 1600 host adapter (controller) number, firmware version and cache DRAM size are displayed in the second portion of the BIOS message. The numbering of the controllers follows the PCI slot scanning order used by the host motherboard.

MegaRAID Enterprise 1600 Card Layout

Step 9 - Install the MegaRAID 1600 Card

The MegaRAID card can plug into a 32-bit or 64-bit PCI slot that receives 5 V and, optionally, 3.3 V through the motherboard. Choose a PCI slot and align the Mega- RAID controller card bus connector to the slot. Press down gently but firmly to make sure that the card is properly seated in the slot. The bottom edge of the controller card should be flush with the slot. Insert the MegaRAID card in a PCI slot as shown below:

Step 10 - Connect the SCSI Cables to the SCSI Devices

Connect the SCSI cables to the SCSI devices. The MegaRAID Enterprise 1600 controller provides two types of connectors: two internal high-density 68-pin SCSI connectors and four external ultra high-density 68-pin SCSI connectors. Offset connectors are needed for external connectors if stacked.

Step 13 - Run MegaRAID Enterprise 1600 Configuration Utility

Press <Ctrl><M> or <Ctrl><H> to run the MegaRAID Enterprise 1600 Configuration Utility. A screen such as the one shown below displays. See the MegaRAID Configura- tion Software Guide for information about running MegaRAID Configuration Utility.

Step 14 - Installing Software Drivers for the Desired Operating Systems

For driver installation procedures, please refer to the MegaRAID Operating Systems Drivers Guide on the Drivers and Documentation CD.

AMI Corporate Headquarters

American Megatrends Inc.

6145-F Northbelt Parkway,

Norcross, GA 30071-2976

Sales (800)828-9264 • sales@ami.com Main (770)246-8600 • Fax (770)246-8790

Germany:

Carl-Zeiss-Ring 7a

85737 Ismaning, Germany

Tel [49]89-9699-9510 • Fax [49]89-9699-9519

United Kingdom:

Taiwan:

 

9th Floor Hayes Gate House

Suite A, Floor 6, No. 150

 

27 Uxbridge Road

Tun Hwa N. Road

 

Hayes, Middlesex UB4 OJN, U.K.

Taipei, Taiwan, R.O.C.

 

Tel [44]208-848-8686 • Fax [44]208-848-8588

Tel [886]2-2716-0036 • Fax [886]2-2718-1121

 

Japan:

Korea:

w w w . a m i . c o m

2-5-15 Sotokanda K Bld. 6F

Suite 3F-B, 773-6,

Sotokanda Chiyoda-ku

Ryucksam-Dong, Kangnam-Ku

 

Tokyo, 101, Japan

Seoul, 135-080, Korea

 

Tel [81]3-3526-9708 • Fax [81]3-3526-9701

Tel [82]2-569-5689 • Fax: [82] 2-569-4689

 

© 2000 American Megatrends Inc. All rights reserved. Printed in the U.S.A.

Page 2
Image 2
American Megatrends MegaRAID Enterprise 1600 Card Layout, Quick Hardware Installation Guide, w w w . a m i . c o m