:DOO0RXQWLQJRI836RSWLRQDO
APC
Note: Position the On/Off switch to the right for horizontal mounting, to the top for vertical.
|
|
|
|
| Vertical Mounting |
| ||
|
|
|
|
| Only |
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| Horizontal and Vertical |
|
|
|
|
|
|
|
| Mounting |
|
|
|
|
|
|
|
|
|
|
|
| Horizontal Mounting |
| |
|
|
|
| |||||
|
|
|
|
|
| Only |
| |
1. Hold this page against the wall with the appropriate edge parallel to the floor. |
|
|
|
|
| |||
|
|
|
|
| ||||
2. Use thumbtacks to hold this page in place. Make sure the template circles line up where you want | 3. Install fasteners at the marked locations. Leave the head of both fasteners 5/16" (8 mm) out from | |||||||
| the mounting fasteners to be installed. Use a sharp nail or pin to puncture the center of each | the surface of the wall. Fasteners must be able to support 15 lb (6.8 kg). | ||||||
| appropriate template circle to mark the wall. | 4. Mount APC | ||||||
|
|
|
| vertical mounting, slide the unit down into place. For horizontal mounting, turn it slightly | ||||
|
|
|
| counterclockwise until it is securely in place. |
&LUFXLW%UHDNHU
If APC
2UGHU5HSODFHPHQW%DWWHU\
The APC part number for APC
%DWWHU\5HSODFHPHQW
Battery replacement is a safe procedure, isolated from electrical hazards.
Do not replace the battery when the UPS is
Please consult the diagrams in the “Connect Battery Wire” procedure during this procedure.
Procedure:
1. | Switch “Off”, and unplug all equipment from APC |
2. | Switch “Off” APC |
3. | Refer to the “Connect battery wire” (Step 1) section of the manual for instructions on |
| how to open the battery compartment. |
4. | Disconnect the battery wires one at a time. |
5. | Grasp each wire connector and pull straight back. Take care not to pull the wires. |
6. | Remove the old battery. |
7. | Connect the red wire to the positive (+) battery terminal of the replacement battery. |
| Connect the black wire to the negative |
8. | Tip the new battery, terminal end first, into the battery compartment. |
7URXEOHVKRRWLQJ
Symptom
If the UPS is switched “On,” outlets are not working, and the On Line
Circuit breaker popped up.
UPS does not provide expected runtime.
UPS fails to power the connected equipment during utility failure or Self
On Battery indicator is lit and is accompanied by a
Possible Cause
The battery wire is not connected.
The outlets are overloaded.
The battery is not charged.
The battery is depleted by frequent power outages.
The Battery Power Supplied outlets are overloaded.
The Battery Power Supplied outlets are severely overloaded.
Solution
Connect the battery wire as shown in Step 1 of the installation instructions (front page of the User’s Manual.).
Unplug one piece (or more) of equipment from the UPS and reset the breaker by pressing the button in.
UPS does not charge the battery when it is turned “Off.” Always keep the UPS “On” when utility power is available.
After saving files and switching “Off” the computer, switch the UPS “Off” during extended power
Unplug one piece of equipment from the Battery Power Supplied outlets.
1.Unplug one piece of equipment from the Battery Power Supplied outlets.
2.Perform the UPS Shutdown Procedure
3.Switch the On/Off switch to “Off,” and then “On” again.
If no overload alarm is sounded when the
Press the battery gently until the retaining clip snaps into place. |
Note: Small sparks at the battery connections are normal during connection.
9.Slide the battery compartment cover back into place. The new battery must be charged for at least 4 hours before full runtime can be expected.
Note: The spent battery must be recycled. Deliver the battery to an appropriate recycling facility or return it (in the new battery’s packing material) to APC. See the new battery instructions for additional recycling information.
8366WRUDJH
Before storing, charge the UPS for at least 10 hours.
Store the UPS covered and upright in a cool, dry location.
Extended Storage |
|
|
| |
| Storage Temperature | Recharge Frequency | Charging Duration | |
| 5 to 86oF | Every 6 Months | 10 Hours | |
| 86 to 113oF | (30 to 45oC) | Every Month | 10 Hours |
6HUYLFH
Note: If the UPS requires service, do not return it to the dealer! The following steps should be taken.
1.Consult the Troubleshooting section to eliminate common problems.
2.Verify that the circuit breaker is not tripped. A tripped circuit breaker is the most common UPS problem!
3.If the problem persists, consult the APC web site (www.apcc.com) or contact APC at
∙Record the model number of the UPS, the serial number, and the date purchased. Be prepared to troubleshoot the problem over the telephone with a technician If this is not successful, the technician will issue a Return Merchandise Authorization Number (RMA#) and a shipping address.
4.If customer service troubleshooting is unsuccessful:
∙If the UPS is under warranty, repairs are free.
∙If the warranty has expired, there is a repair charge.
5.Disconnect the black wire from the UPS battery.
6SHFLILFDWLRQV
Acceptable Input Voltage
“On Battery” Output Voltage
Frequency Limits (“On Line”)
Maximum Load - Battery Power
Supplied Outlets
Maximum Load - Surge Protected Only Outlets
Typical Recharge Time
Operating /Storage Temperature
Operating and Storage Relative
Humidity
Operating Elevation/ Storage Elevation
UPS Size (H x W x D) excluding cord
UPS Weight / Shipping Weight
EMI Classification
0 - 150 Vac, Single Phase
57 - 63 Hz
280 VA, 170 W
10 A
12 hours from total discharge
32 to 95°F (0 to 35°C) / | 5 to 113 °F |
0 to 95%, | |
|
|
0 to +10,000 ft (0 to +3,000 m) | 0 to +50,000 ft (0 to +15,000 m) |
2.7 x 17.0 x 7.0 in | (6.9 x 43.2 x 17.8 cm) |
8.0 lb (3.6 kg) | 8.5 lb (3.9 kg) |
FCC/DOC Class B
Department of Transportation (DOT) regulations require that the black battery wire be disconnected before shipping the UPS back to APC. The “Connect Battery Wire” instructions and graphics on the front page show how to access the wire.
6.Pack the UPS in its original packaging. If the original packing is not available, ask customer service about obtaining a new set. Pack the UPS properly to avoid damage in transit.
Note: Never use Styrofoam™ beads for packaging. Damage sustained in transit is not covered under warranty (insuring the package for full value is recommended).
7.Write the RMA# on the outside of the package.
8.Return the UPS by insured, prepaid carrier to the address given to you by customer service.
$3&&RQWDFW,QIRUPDWLRQ
:DUUDQW\
Users must contact customer service to troubleshoot the unit before returning the unit to APC. The standard warranty is 2 years from date of purchase. APC’s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Customer Service. APC will ship out the replacement unit once the defective unit has been received by the repair department or cross ship upon the provision of a valid credit card number. The customer pays for the shipping to APC, and APC pays ground freight transportation costs back to the customer.
USA/Canada ……………. | 1.800.800.4272 |
Mexico…………………… | 292.0253 / 292.0255 |
Brazil ……………………. | 0800.12.72.1 |
|
|
| Worldwide ……………… | 1.401.789.5735 |
|
| |
Internet and | http://www.apcc.com |
|
Tech Support |
| |
|
|