American Power Conversion installation instructions User’s Guide, Back-UPS ES 350/550

Models: 350/550

1 2
Download 2 pages 9.62 Kb
Page 1
Image 1
Back-UPS®ES 350/550

®

Back-UPS®ES 350/550

www.apc.com

User’s Guide

 

Connect Battery

1 For safety, the Back-UPS ES is shipped with one battery wire disconnected. The Back-UPS ES will not operate until the wire is connected to the touch safe battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.

1

TURN the Back-UPS ES over and

slide the battery compartment

cover off of the battery housing.

2

LIFT the battery out of the compartment and connect the black wire to the negative (-) battery

terminal. Ensure the batteries are installed as shown below.

Slide the battery compartment cover

3 completely onto the Back-UPS ES.

Back-UPS ES 350

Back-UPS ES 550

 

2

Connect Equipment

 

Place the Back-UPS ES to avoid:

 

- Direct sunlight

 

- Excessive heat

Battery Backup
Surge Protection

- Excessive humidity or contact with fluids

These outlets are powered whenever the Back-UPS ES is

Plug the Back-UPS ES power cord directly into a wall outlet; not a

surge protector or power strip.

switched ON. During a power outage or other utility problems

 

(brownouts, over-voltages), these outlets will be powered for a limited time by the Back-UPS ES. Plug your computer, monitor, and two other data-sensitive devices (external disk or tape drive) into these outlets.

 

®

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

w w w.apc.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CORD

User’s GuideConnect BatteryConnect Equipment Battery Backup Battery Backup Surge Protection Surge Protection

Connect FAX/Modem/Phone

Back-UPS ES protects a single line (2-wire) fax, modem or phone from surges when it is connected through the Back-UPS ES as shown.

Connect Computer Cable

The supplied cable and software provide automatic file saving and shutdown of the operating system in the case of a sustained power outage.

Connect the cable to the Data Port of the Back-UPS ES. Connect the other end of the cable to the USB port on your computer. The software will automatically find the USB Port of your computer.

POWER ON/

REPLACE BATTERY

INDICATOR

Surge Protection Only Surge Protection Only Status Indicators

Back-UPS ES 5 5 0

Power On Power On and

Replace Battery Install Software

BUILDING WIRING See the Troubleshooting section for additional assistance. FAULT INDICATOR Manual background

FROM WALL JACK

DATALINE OUTPUT TO Manual background DSL MODEM or PHONE

Building

Wiring

Fault

CAUTION - Refer to bottom of unit for safety markings.

 

Wall

Circut Breaker

 

Push to Reset

 

Outlet

 

 

 

 

 

 

 

 

 

 

 

 

Modem/

 

 

 

Phone/Fax

 

 

 

 

 

 

 

 

 

Data Port

 

 

 

 

 

 

 

 

 

 

 

Surge Protection Only

 

TO COMPUTER

CIRCUIT BREAKER

 

 

 

 

 

USB PORT

PUSH TO RESET

 

 

These outlets provide full-time protection from surges even if

 

 

 

 

 

 

the Back-UPS ES is switched OFF. Plug your printer, fax

 

 

 

 

 

 

 

 

machine, scanner, or other peripherals that do not need

 

 

 

 

 

 

 

 

battery power into these outlets.

Status Indicators

 

 

 

 

 

 

 

 

 

 

 

 

Power On and

The Back-UPS ES indicates operating status using a combination of visual and audible indicators.

Use the following table to identify the status of the Back-UPS ES.

 

 

 

 

 

 

Install Software

 

 

 

 

 

 

 

 

Status

(Replace Battery - Red)

 

Audible Indication

Alarm Terminates

 

 

 

 

Visual Indications

 

 

 

 

 

 

(Power On - Green)

 

 

When

 

Press the ON/OFF switch to power the unit

 

 

 

 

 

 

 

 

Power On - UPS is supplying conditioned

Power On LED - ON

 

None

Not applicable.

 

3 ON.

 

utility power to the load.

 

 

 

 

 

 

 

On Battery - UPS is supplying battery

Power On LED

- ON (off

 

Beeping 4 times every

UPS transfers back to

 

A single short beep and the green “Power On”

 

power to the load connected to the Battery

during beep)

 

 

30 seconds

Power On operation, or

 

indicator confirms that Back-UPS ES is on and

 

outlets.

 

 

 

 

when UPS is turned off.

 

 

 

 

 

 

 

 

 

 

Low Battery Warning - UPS is supplying

Power on LED

- flashing

 

Rapid beeping (every

UPS transfers back to

 

ready to provide protection.

 

 

 

 

battery power to the load connected to the

 

 

 

1/2 second)

normal operation, or

 

The Back-UPS ES should charge for at least

 

Battery outlets and the battery is near

 

 

 

 

when UPS is turned off.

 

 

exhaustion.

 

 

 

 

 

 

16 hours to ensure sufficient runtime. The unit

 

 

 

 

 

 

 

 

 

 

Replace Battery - The battery is

Replace Battery LED -

 

Constant tone

UPS turned off with the

 

is being charged whenever it is connected to

 

 

disconnected.

flashing

 

 

 

power switch.

 

utility power, whether the unit is turned ON or

 

 

 

 

 

 

 

 

 

OFF.

 

 

The battery is in need of charging or is at

Power On and Replace

 

Constant tone

 

 

 

 

 

the end of its usual life and must be

Battery LEDs-

Flashing

 

 

 

 

If the red Building Wiring Fault indicator

 

 

replaced.

(alternating)

 

 

 

 

 

(located on the end near the power cord) is lit,

 

 

Overload Shutdown - During On Battery

None

 

 

Constant tone

UPS turned off with the

 

your building wiring presents a shock hazard

 

 

operation a battery power supplied outlet

 

 

 

 

power switch.

 

 

 

overload was detected.

 

 

 

 

 

 

that should be corrected by a qualified

 

 

 

 

 

 

 

 

 

 

 

Sleep Mode - During On Battery operation

None

 

 

Beeping once every 4

Utility power is restored,

 

electrician.

 

 

the battery power has been completely

 

 

 

seconds

or if utility power is not

 

 

 

 

exhausted and the UPS is waiting for utility

 

 

 

 

restored within 32

 

Install the PowerChute Personal® Edition

 

 

power to return to normal.

 

 

 

 

seconds, or the UPS is

 

 

 

 

 

 

 

 

turned off.

 

software

 

 

 

 

 

 

 

 

 

 

Building Wiring Fault - Your building

Building Wiring Fault LED

 

None

UPS is unplugged, or is

 

Place the PowerChute Personal Edition CD-

 

 

wiring presents a shock hazard that should

(red) - ON

 

 

 

plugged into a properly

 

 

 

be corrected by a licensed electrician.

 

 

 

 

wired outlet.

 

ROM into your computer and follow the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

installation instructions on the screen.

 

See the Troubleshooting section for additional assistance.

 

 

 

 

 

 

 

 

 

 