Troubleshooting

 

Troubleshooting

Use the table below to solve minor Back-UPS ES installation or operation problems. Consult APC Online Technical Support or call APC

 

 

Technical Support for assistance with problems that cannot be resolved using the table below:

 

 

 

 

 

Problem

 

 

Probable Cause

 

Solution

 

 

 

 

 

 

Back-UPS ES will not turn on.

 

 

The battery is disconnected, and either power is unavailable

 

Connect the battery (see Connect Battery) and ensure power is available at the wall

 

 

 

 

 

at the wall outlet, or utility power is having a “brownout” or

 

outlet. If battery is connected and power is unavailable, the unit can be “cold

 

 

 

 

 

an “over voltage” condition.

 

started” (operated on battery power) by holding the power button down until two

 

 

 

 

 

 

 

beeps are heard.

 

 

No power available at the Surge Protection

 

 

Surge Protection outlets were overloaded.

 

Reduce the amount of equipment plugged into the Surge Protection outlets.

 

 

 

outlets.

 

 

 

 

Ensure the fuse or circuit breaker for the outlet is not tripped, and that the wall switch

 

 

 

 

 

 

Utility power not available at the wall outlet.

 

 

 

 

 

 

 

 

 

controlling the outlet (if any) is in the ON position.

 

 

 

Back-UPS is on, but Replace Battery indicator

 

 

Battery is disconnected.

 

Connect the battery (see Connect Battery diagram).

 

 

flashes, and unit emits a constant tone.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connected equipment loses power.

 

 

Equipment is connected to the “Surge Protection” outlets.

 

Ensure the equipment you want to stay powered during a power failure is plugged

 

 

 

 

 

 

 

into the “Battery Backup plus Surge Protection” outlets and NOT the “Surge

 

 

 

 

 

 

 

Protection Only” outlets.

 

 

 

 

 

The Back-UPS ES is overloaded.

 

Make sure the equipment plugged into the outlets of the unit are not overloading its

 

 

 

 

 

 

capacity. Try removing some of the equipment and see if the problem continues.

 

 

 

 

 

 

 

 

 

 

 

 

PowerChute Personal Edition software has performed a

 

The Back-UPS ES is operating normally.

 

 

 

 

 

shutdown due to a power failure.

 

 

 

 

 

 

 

 

The Back-UPS ES has exhausted its available battery

 

The Back-UPS ES can only operate on battery power for a limited amount of time.

 

 

 

 

 

power.

 

The unit will eventually turn off when the available battery power has been used.

 

 

 

 

 

 

 

Allow the unit to recharge for 16 hours before expecting maximum runtime.

 

 

 

 

 

Connected equipment does not accept the step-

 

The output waveform is designed for computers and computer-related equipment. It

 

 

 

 

 

approximated sine waveform from the Back-UPS ES.

 

is not designed for use with motor-type equipment.

 

 

 

 

 

The Back-UPS ES may require service.

 

Contact APC Technical Support for further troubleshooting.

 

 

 

 

 

 

 

 

 

 

 

The Power On indicator is lit and the Back-

 

 

The Back-UPS ES is On Battery.

 

The Back-UPS ES is operating normally, and using battery power. Once On Battery,

 

 

UPS ES beeps four times every 30 seconds.

 

 

 

 

you may want to save your current work, power down your equipment, and turn the

 

 

 

 

 

 

 

unit OFF. Once normal power is restored, you may turn the unit back ON, and power

 

 

 

 

 

 

 

your equipment.

 

 

 

 

 

 

 

 

 

 

 

The Power On indicator flashes and the Back-

 

 

Battery capacity is low (about 2 minutes of use remaining).

 

The Back-UPS ES is about to shut off due to a low battery charge condition! When

 

 

UPS beeps twice per second at the same time.

 

 

 

the unit beeps twice every second, the battery has about 2 minutes of power

 

 

 

 

 

 

 

remaining. Immediately power down your computer ,and turn the unit OFF. When

 

 

 

 

 

 

 

normal power returns, the unit will recharge the battery.

 

 

Building Wiring Fault indicator is lit.

 

 

Your building wiring presents a shock hazard. Using the

 

Call a qualified electrician for service.

 

 

 

 

 

Back-UPS with this condition will void the warranty.

 

 

 

 

 

Inadequate runtime.

 

 

The battery is not fully charged.

 

Allow the unit to charge by leaving it plugged into the wall at least 16 hours.

 

 

 

 

 

 

Battery is near the end of useful life.

 

As a battery ages, the amount of runtime available will decrease. You can replace

 

 

 

 

 

 

 

 

the battery by ordering one at www.apc.com. Batteries also age prematurely if the

 

 

 

 

 

 

 

 

Back-UPS ES is placed near excessive heat.

 

 

 

 

 

 

 

 

 

 

 

 

No phone/fax/DSL/cable or network signal

 

 

Data line from the ISP or wall outlet is connected to the

 

Make sure the data line from the wall outlet is connected to the jack labeled “Wall

 

 

from the Back-UPS.

 

 

wrong jack on the Back-UPS.

 

Outlet”, or “Cable In” (Cable/DSS/CATV).

 

 

 

 

 

 

 

 

 

 

Internet connection llost during power outage.

 

 

Modem losthas AClostpowerAC Power. .

 

Plug the AC power cord of the modem into one of the four “Battery Back-up plus

 

 

 

 

 

Plug the modem’s AC power cord into one of the “Battery Back-up Plus Surge Protec-

 

 

 

 

 

 

 

Surge Protection” outlets.

 

 

 

 

 

 

 

tion outlets”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications

Model

 

BE650G

Input

Voltage

120 Vrms nominal

 

 

 

 

Frequency

50 - 60 Hz (auto-sensing)

 

 

 

 

Brownout Transfer

88 Vrms, typical

 

 

 

 

Over-voltage Transfer

139 Vrms, typical

 

 

 

Output

UPS Capacity (4 outlets)

650 VA / 390 W

 

 

 

 

Total Amperage (8 outlets)

12 Amps (including UPS output)

 

 

 

 

Voltage - On Battery

115 Vrms + 8% (step-approximated sine wave)

 

 

 

 

Frequency - On Battery

50 - 60 Hz + 1 Hz

 

 

 

 

Transfer Time

6 ms typical, 10 ms maximum

 

 

 

Protection and

AC Surge Protection

Full time, 375 joules

Filter

 

 

 

 

 

 

Phone/fax/DSL Surge

Single line (2-wire)

 

Protection

 

 

 

 

 

Cable/CATV/DSS Surge

One Coax Input/Output

 

Protection

 

 

 

 

 

Network Surge Protection

10/100Base-T Ethernet

 

 

 

 

EMI/RFI Filter

Full time

 

 

 

 

AC Input

Resettable circuit breaker

 

 

 

Battery

Type

Sealed, maintenance-free lead acid

 

 

 

 

Average Life

3 - 5 years depending on the number of discharge cycles

 

 

and environmental temperature

 

 

 

Physical

Net Weight

14.3 lb. (6.5 Kg.)

 

 

 

 

Size

3.54" (H) x 12.6" (W) x 6.97" (D)

 

 

(9.0 x 32.0 x 17.7 cm)

 

 

 

 

Operating Temperature

+32oF to 104oF (0oC to 40oC)

 

Storage Temperature

+5oF to 113oF (-15oC to 45oC)

 

Operating Relative Humidity

0 to 95% non-condensing

 

 

 

 

Operating Elevation

0 to 10,000 ft (0 to 3,000m)

 

 

 

Safety and

Safety Approvals

TUV C-US certified; UL 1778 standard per CSA

Regulatory

 

standard C22.2 No. 107.1, FCC part 68 &

 

 

FCC part 15 Class B, NOM certified

 

 

 

 

EMC Compliance

Notice: This device complies with part 68 and part 15 of

 

 

the FCC rules. Operation is subject to the following two

 

 

conditions: (1) This device may not cause harmful

 

 

interference, and (2) This device must accept any

 

 

interference received, including interference that may

 

 

cause undesired operation.

 

 

“On the bottom of this equipment is a label that contains,

 

 

among other information, the FCC registration number

 

 

and ringer equivalence number (REN) for this equipment.

 

 

If requested, this information must be provided to the

 

 

telephone company.”

 

 

 

Order Replacement Battery

Replace with an APC qualified battery. Replacement batteries can be ordered from www.apc.com (valid credit card required). The replacement battery part number for this Back-UPS is: RBC17.

Warranty

The standard warranty is 3 years from the date of purchase. APC’s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Technical Support. APC will ship the replacement unit once the defective unit is received by the repair department or cross-ship upon the provision of a valid credit card number. The customer pays for shipping to APC, and APC pays ground freight transportation costs back to the customer.

Service

Please DO NOT RETURN Back-UPS ES to the place of purchase under any circumstances.

1.Consult the Troubleshooting section to eliminate common problems.

2.Verify the battery is connected (see Connect Battery) and that the Circuit Breaker is not tripped (see Troubleshooting section).

If you still have problems or questions, please contact APC via the internet or at one of the phone numbers listed below.

3.Before contacting APC, please be sure to record the date purchased, UPS model, and serial number (on bottom of unit).

4.Be prepared to troubleshoot the problem over the telephone with a Technical Support Representative. If this is not successful, the representative will issue a Return Material Authorization Number (RMA#) and a shipping address.

5.Pack the unit in its original packaging. If the original packaging is not available, ask APC Technical Support about obtaining a new set. Pack the unit properly to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty (insuring the package for full value is recommended).

6.Write the RMA# on the outside of the package.

7.Return the unit by insured carrier to the address given to you by APC Technical Support.

APC Contact Information

Online Technical Support:

http://support.apc.com

 

http://www.apc.com/support

 

esupport@apcc.com

Web Site:

www.apc.com

USA/Canada:

1.800.800.4272

Mexico:

+52.292.0253 / 52.292.0255

Brazil:

+0800.12.72.1

Worldwide:

+1.401.789.5735

Page 2
Image 2
American Power Conversion ES 650 Specifications, Order Replacement Battery, Warranty, Service, APC Contact Information