®

1

CONTENTS

2 CONNECT BATTERY CARTRIDGE

3 OPERATING ENVIRONMENT

 

 

 

 

www.apc.com

 

RJ-11

RJ-11

 

 

 

 

 

 

 

 

 

 

 

 

Back-UPS®RS 1000

 

 

USB

RJ-45

 

32 - 104oF (0 - 40oC)

 

 

 

 

 

 

 

24 inches

Back-UPS®RS 1500

 

 

®

 

 

 

 

 

 

 

 

 

 

60 cm

 

User’s Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 CONNECT EQUIPMENT / POWER

5 CONNECT PHONE/MODEM/FAX

6 CONNECT 10/100 Base-T or VOIP

7 CONNECT INTERFACE CABLE

INSTALL SOFTWARE ON

 

 

 

 

Phone Jack

 

For connection of APC’s optional

10 COMPUTER

 

external 24-volt battery pack

(BR24BP) to the Back-UPS RS 1000

and Back-UPS RS 1500.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall

 

Wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet

Outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Network Jack

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TVSS GND

 

 

 

 

To Computer USB

 

 

 

Follow the

 

 

 

 

 

 

 

 

 

on-screen

 

 

 

 

 

 

 

 

Port

 

 

 

Monitor

 

 

 

 

 

Computer

USB

Data Port

 

 

instructions.

 

 

 

 

 

RJ-45

BR24BP Battery Pack

 

 

 

 

 

 

 

Network Port

10/100 Base-T

 

 

 

 

 

 

 

 

 

Computer

 

 

VOIP

 

 

 

 

 

 

 

Modem/

 

 

 

 

 

 

 

 

 

Computer

Modem Port

 

 

 

 

 

 

 

 

 

 

Phone/Fax

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

Computer

 

 

Macintosh Users - for full USB

 

BATTERY

 

 

 

 

 

 

 

 

performance, use OS 9.22 or higher.

 

BACKUP

 

 

 

 

 

 

 

 

If Autoplay is not enabled on the computer,

Printer or Scanner

External Disk or

8 SWITCH ON THE BACK-UPS

 

 

9 ORIENTATION

 

 

 

 

proceed as follows:

 

 

 

 

 

 

 

 

 

 

OR

CD / DVD Drive

Note: Allow the Back-UPS to charge for a

When Self-Test has successfully

 

 

 

1.

On the computer desktop of the display,

 

SURGE ONLY

full eight (8) hours prior to use.

 

 

completed, only the green On Line

 

 

 

2.

double-click on My Computer.

 

 

Press the front panel Power ON/OFF switch

 

indicator will be lit.

 

 

 

Double-click on the CD-ROM drive icon

 

 

 

 

 

 

 

 

and follow the on-screen instructions.

 

 

and observe that the following events occur

If the internal battery cartridge is not

 

 

 

 

FAX

 

after pressing and releasing the switch:

 

connected (see Step 2 above), the green

 

 

 

 

 

 

 

The green On Line indicator flashes.

 

On Line indicator and red Replace Battery

 

 

 

 

 

 

 

 

 

indicators will light. The Back-UPS will

 

 

 

 

 

 

 

 

The yellow On Battery indicator lights

 

 

 

 

 

 

also emit a chirping sound.

 

 

 

 

 

while a Self-Test is being performed.

 

 

 

 

11

CONNECT TVSS

GROUND

STATUS INDICATORS AND ALARMS

SERVICE

The Back-UPS features a transient voltage surge-suppression (TVSS) screw for connecting the ground lead on additional surge suppression devices such as network and data line surge protectors.

Wall

Outlet

From Data Line

TVSS

TVSS GND

Modem/

Phone/Fax

There are four status indicators (lights) on the front panel of the Back-UPS (On Line, On Battery, Overload, and Replace Battery).

On Line

On Battery

Overload

Replace Battery

On Line (green) - is lit whenever utility power is powering the Battery Backup outlets.

On Battery (yellow) - is lit whenever the battery of the Back-UPS is powering equipment connected to the Battery Backup Outlets.

Four Beeps Every 30 Seconds - this alarm is sounded whenever the Back-UPS is running On Battery. Consider saving work in progress.

Continuous Beeping - this alarm is sounded whenever a low battery condition is reached. Battery run-time is very low.

Promptly save any work in progress and exit all open applications. Shutdown the operating system, computer and the Back-

UPS.

Overload (red) - is lit whenever power demand has exceeded the capacity of the Back-UPS.

Continuous Tone - this alarm is sounded whenever the Battery Backup outlets are overloaded.

Circuit Breaker - the circuit breaker button located on the rear panel of the Back-UPS will stick out if an overload condition forces the Back-UPS to disconnect itself from utility power. If the button sticks out, disconnect non-essential equipment. Reset the circuit breaker by pushing the button inward.

Replace Battery (red) - is lit whenever the battery is near the end of its useful life, or if the battery is not connected (see above). A battery that is near the end of its useful life has insufficient run-time and should be replaced.

Chirps for 1 Minute Every 5 Hours - this alarm is sounded whenever the battery has failed the automatic diagnostic test.

If the Back-UPS arrived damaged, notify the carrier.

If the Back-UPS requires service, do not return it to the dealer. The following steps should be taken:

1.Consult the Troubleshooting section to eliminate common problems.

2.If the problem persists, go to http:// www.apc.com/support/.

3.If the problem still persists, contact APC Technical Support.

4.Have the Back-UPS model number, serial number and date of purchase available. Be prepared to troubleshoot the problem with an APC Technical Support representative. If this is not successful, APC will issue a Return Merchandise Authorization (RMA) number and a shipping address.

Page 1
Image 1
American Power Conversion RS 1000 user manual Contents CON Nect Battery Cartridge, Connect Interface Cable, Computer