VALVE ASSEMBLY (1340.825; 1340.855; 1340.865)

VALVE ASSEMBLY (1340.825; 1340.855; 1340.865)

Install LOCKNUTS (1), METAL WASHERS (3) and RUBBER WASHERS (2) onto valve shanks.

Push TUBING (14) ends into VALVE (4) side outlets. Insert VALVES (4) into mounting holes from underside of ledge.

Press TEE (5) onto SPOUT SHANK (6) making certain that the O-RING (7) is properly seated on SHANK (6). Push COUPLING (8) into TEE (5) and attach to SPOUT SHANK (6) and tighten.

Thread of VALVE BODY (4) should extend at least 5/16 inch above MOUNTING SURFACE (11). If necessary, adjust LOCKNUT (1).

Place RUBBER RING (10) into ESCUTCHEONS (9) and thread onto valves until snug against internal stop.

Tighten LOCKNUT (1) to secure VALVE (4) position.

MOUNTING

SURFACE

 

Slide FERRULE (12) and COUPLING NUT (13) to outlet of VALVE (4)

 

and tighten COUPLING NUT (13) firmly.

 

Place WASHER (16) on top of VALVE ASSEMBLY (4).

Manual background15

Manual background10

11

9 Manual backgroundManual background

16

10

Thread VALVE ACTUATORS (15) onto VALVES (4) and torque VALVE

 

 

 

 

ACTUATOR 12-15 ft. lbs, (12-20Nm).

 

 

 

7

Connect water supply to VALVES (4) with 1/2" IPS FLEXIBLE SUPPLIES or

 

 

 

 

12

 

 

3/8" O.D. BULL-NOSE RISERS. Use adjustable wrench to tighten connections.

4

13

6

Do not over tighten. Be careful not to kink copper supply when bending. Use

 

 

16

tubing cutter to cut to proper length.

 

 

 

HOT

 

 

 

 

 

 

 

 

10

9

 

 

12

 

 

 

14

 

 

 

 

 

 

 

 

 

5/16'' MIN.

4

11

MOUNTING

5

 

 

 

 

SURFACE

8

4

 

 

 

 

 

3

2

 

13

COLD

 

1

 

1/2" IPS FLEXIBLE SUPPLIES or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/8" O.D. BULL-NOSE RISERS

 

 

 

 

 

COUPLING NUT

 

￿￿VALVE ASSEMBLY (1340.725)

For Cold or Tempered Water Supply

Valve assembly is same as two handle lavatory faucets. See above instructions for assembly, (1340.725 Single Valve Faucet) is for Cold or Tempered water only.

10

9

MOUNTING

11

 

SURFACE

 

Manual background15

9Manual backgroundManual background

10 Manual backgroundManual background

5/16'' MIN.

4

11

MOUNTING

7

 

 

 

 

SURFACE

16

 

 

 

 

 

 

2

 

6

 

 

 

 

 

12

 

3

1

 

5

 

 

 

 

 

 

 

 

 

8

4

13

COLD OR

14

TEMPERED

WATER

1/2" IPS FLEXIBLE SUPPLIES or

￿￿￿￿￿￿￿

3/8" O.D. BULL-NOSE RISER

COUPLING NUT