American Standard 1340.855, 1340.865, 1340.825 installation instructions Care Instructions

Models: 1340.825 1340.865 1340.855

1 4
Download 4 pages 62.76 Kb
Page 3
Image 3

INSTALL HANDLES

Remove INDEX BUTTON (1; 2) and loosen SET SCREW (3) with a 2.5mm hex wrench.

Install HANDLES (4) onto VALVE STEM (5).

Tighten SET SCREWS (3) with 2.5mm Hex Wrench.

Replace INDEX BUTTONS. Red (1) in Left HANDLE (4) Blue (2) in Right HANDLE (4).

1

4

3

3

4

2.5mm

HEX WRENCH

5

2

￿TEST INSTALLED FITTING

Turn on water supplies and check connections for leaks.

PRESS HANDLE

DOWN TO OPERATE

 

Remove AERATOR (1) with KEY (2) supplied.

 

Operate HOT and COLD HANDLES by pressing down on HANDLES.

Both Hot and Cold handles are set for approximately 8 second operating cycles.

Replace AERATOR (1).

1

2

￿TO ADJUST CYCLE TIME

Remove HANDLE (1) by removing INDEX BUTTON (2) and SET SCREW (3) with a 2.5mm hex wrench.

Pull off HANDLE (1).

To increase cycle time, turn the gray PLASTIC ADJUSTING KNOB (4) clockwise.

To decrease cycle time, turn the gray PLASTIC

ADJUSTING KNOB (4) counter-clockwise.

Replace SET SCREW (3), INDEX BUTTON (2) and HANDLE (1). Test faucet for proper operation and cycle time.

23 1

2.5mm HEX WRENCH

TO DECREASE

TO INCREASE

CYCLE TIME

CYCLE TIME

ROTATE

ROTATE

COUNTER-

CLOCKWISE

CLOCKWISE

 

4

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

￿SERVICE

Remove HANDLE (1). Refer to Step 4 for handle removal.

Remove ACTUATOR ASSEMBLY (2).

Remove WASHER (3). Pull out VALVE ASSEMBLY (4) and

FILTER SCREEN (5).

Inspect that VALVE ASSEMBLY (4), FILTER SCREEN (5) and VALVE SEAT (6) are clean and free from debris. VALVE ASSEMBLY (3) and FILTER SCREEN (5) can be cleaned with soap and water.

Replace FILTER SCREEN (5) and VALVE ASSEMBLY (4). Place WASHER (3) on top of VALVE ASSEMBLY (4). Thread VALVE ACTUATOR (2) onto faucet. Torque VALVE ACTUATOR (2) to 12-15 ft. lbs (15-20 Nm).

Replace HANDLE (1).

1

REMOVE

REPLACE

2

3

 

4

￿￿￿￿￿￿￿

6

5

 

Page 3
Image 3
American Standard 1340.855, 1340.865, 1340.825 installation instructions Care Instructions

1340.825, 1340.865, 1340.855 specifications

The American Standard 1340.855, 1340.825, and 1340.865 are versatile and high-quality air conditioning units designed to provide optimal comfort, energy efficiency, and reliability in various residential settings. Each model comes with unique features and technologies tailored to meet diverse cooling needs while ensuring long-lasting performance.

The American Standard 1340.855 is renowned for its advanced energy efficiency, boasting a high SEER (Seasonal Energy Efficiency Ratio) rating. This model incorporates a two-stage cooling system, allowing it to operate at both high and low capacities based on the cooling demand. This feature not only ensures consistent indoor temperatures but also reduces energy consumption. The 1340.855 is equipped with a variable speed blower motor that enhances comfort by providing more precise airflow adjustments.

In contrast, the American Standard 1340.825 emphasizes affordability without compromising efficiency. This model is designed for those seeking reliable cooling at a competitive price point. It features a single-stage compressor and uses eco-friendly refrigerant, making it a suitable choice for environmentally-conscious homeowners. The durable cabinet design offers enhanced protection against the elements, ensuring that the unit remains functional and efficient for years to come.

The American Standard 1340.865 stands out with its smart home compatibility. This model integrates seamlessly with various home automation systems, allowing users to control their cooling system remotely via smartphone applications. It also features advanced features such as a programmable thermostat and Wi-Fi connectivity, providing users with the ability to optimize their energy usage and reduce utility bills effectively. The 1340.865 employs a multi-position installation option, making it adaptable for various home layouts and configurations.

All three models share a commitment to sound performance, designed with noise-reducing technology to operate quietly in the background. They also come with a robust warranty, ensuring peace of mind for homeowners investing in their comfort. Overall, the American Standard 1340.855, 1340.825, and 1340.865 combine cutting-edge technology, energy efficiency, and user-friendly features, making them exceptional choices for any home heating and cooling system.