ELECTRICAL INSTALLATION INSTRUCTIONS

ELECTRICAL INSTALLATION INSTRUCTIONS

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING:

When using electrical products, basic precautions should always be observed, including the following:

1.DANGER: RISK OF ELECTRIC SHOCK

Connect only to a circuit protected by a ground-fault circuit interrupter.

2.Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.Install to permit access for servicing.

4.All building materials and wiring should be routed away from the pump body and heater (if equipped).

The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential. Heater equipped models require a separate 15 amp maximum GFCI circuit.

ELECTRICAL INSTALLATION

SEPARATE

15GFCI OUTLET

120 VAC

WHITE

BLACK

GND.

WHIRLPOOL MOUNTED

AIR SWITCH OR

WALL TIMER

PUMP/MOTOR

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

753449-100 REV. A

(3)

Page 3
Image 3
American Standard 1748 ELECTRICAL INSTALLATION SEPARATE 15GFCI OUTLET, 120 VAC, White, Black, Pump/Motor