American Standard 1749 SERIES installation instructions General Installation Information, Tools

Models: 1749 SERIES

1 4
Download 4 pages 24.67 Kb
Page 1
Image 1
COLONY™ 5'

COLONY™ 5'

INTEGRAL APRON WITH REMOVABLE ACCESS PANEL HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS

1749 SERIES WHIRLPOOL/BATHING POOL

INSTALLATION INSTRUCTIONS

 

 

60"

 

 

 

 

(1524 mm)

 

 

 

12"

 

 

 

 

(305 mm)

 

 

 

 

8-3/4"

 

WATER RETENTION

3/4"

(222 mm)

(6) JETS

FLANGE (3 SIDES)

(19 mm)

 

 

 

 

 

 

 

FINISHED

 

 

 

 

WALL

 

 

 

 

SEE FITTING

 

 

 

21"

 

 

 

(535 mm)

SPECS FOR

 

 

 

 

 

 

 

DIMENSIONS

 

9"

 

 

 

 

 

 

 

 

(229 mm)

 

 

 

 

 

 

42"

 

 

 

PUMP

(1067 mm)

43-1/2"

 

 

 

 

 

 

 

(1105 mm)

 

 

 

 

 

 

CUTOUT IN FLOOR FOR DRAIN

 

C/L OF

2-3/4"

 

ON/OFF

ACCESS TO PUMP/MOTOR

SUPPLIES

(70 mm)

(2) AIR VALVES

THROUGH REMOVABLE

 

 

 

SWITCH

 

C/L OF DRAIN

FRONT ACCESS PANEL

 

 

 

 

 

C/L OF

 

 

 

 

SHOWER ARM

 

 

 

 

FINISHED

 

 

OPTIONAL TO

1-1/4" WATER

WALL

 

FINISHED FLOOR

RETENTION

C/L OF

 

USUALLY BETWEEN

FLANGE

 

 

65 & 78

(3 SIDES

VALVES

 

(1651 & 1981mm)

& APRON)

 

 

 

C/L OF

12

 

 

C/L OF

 

 

(305mm)

 

 

SPOUT

LEVELING

 

OVERFLOW

 

 

 

OPT.

4

 

TILING

STRINGER

 

2-3/4

 

 

 

(102 mm)

FLANGE

NOT FOR

 

(70mm)

 

 

 

 

 

 

SUPPORT

 

 

 

 

 

 

TOP OF

 

 

 

 

 

UNDERSIDE

DECK

19

 

 

 

18-1/2

OF DECK

 

(485mm)

 

 

 

(470mm)

 

 

 

 

REF.

 

 

 

 

 

 

 

 

ROUGH

 

 

 

DIM

 

 

FLOOR

 

 

 

 

 

 

BATH

1-1/2 N.P.T.M.

 

 

 

 

 

SUPPORT

THREADS

 

 

2-3/4

 

 

MATERIAL

1-1/2 O.D.TAILPIECE

 

(70mm)

 

 

 

 

 

4-5/8

 

 

 

 

 

 

(117mm)

 

THANK YOU...

for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. the whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool. To insure maximum performance and pleasure from this

product, please follow the instructions and cautions.

List of Required Components (not included):

Drain 1583.470*

• Bath Filler*

* see your American Standard Dealer

List of Required Tools and Supplies:

Tools

Supplies

Level

Nails

Tape Measure

Putty

Pipe Wrench

Caulking (waterproof)

Slip Joint Pliers

1 x 3 or 2 x 2

Screw Driver

 

Stringers

Standard

Drop Cloth

 

Woodworking Tools

15 amp GFI

Personal Safety

 

Outlet

 

Equipment

Cement, Plaster,

Caulking Gun

 

Grout

GENERAL SPECIFICATIONS FOR 1749 WHIRLPOOL

INSTALLED SIZE

 

 

 

 

 

 

 

60 x 42 x 19 In.(1525 x 1067 x 483mm)

WEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

112 Lbs. (50 Kg.)

WEIGHT w/WATER

 

 

 

 

 

 

 

 

 

714 Lbs. (324 Kg.)

GAL. TO OVERFLOW

 

 

 

 

 

 

 

 

 

 

 

72 Gal. (274 L)

 

 

 

 

 

 

 

 

 

 

 

WHIRLPOOL MIN. OPERATING VOL.

 

 

 

 

 

 

 

52 Gal. (197 L)

 

 

 

 

 

 

 

BATHING WELL AT SUMP

 

 

 

 

44 x 23 In. (1120 x 585mm)

BATHING WELL AT RIM

 

 

 

 

54 x 26 In. (1370 x 660mm)

 

 

 

 

WATER DEPTH TO OVERFLOW

 

 

 

 

 

13-5/8 In. (346mm)

 

 

 

 

 

FLOOR LOADING

 

 

 

41 Lbs./Sq.Ft. (193 Kgs./Sq.m)

 

 

 

(PROJECTED AREA)

 

 

 

 

 

 

 

 

 

 

 

WHIRLPOOL ELECTRICAL SPECIFICATIONS

PUMP

 

 

 

 

 

1.0 HP, 9.9 AMPS, 120V.

 

 

 

 

 

General Installation Information

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately. After inspection and during installation, protect the bath from construction damage. Before installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks. Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system. Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others.

General Installation Information

IMPORTANT: Water test unit before installation and

enclosure!

Bath may only be installed in a recess type installation.

 

Locate studs as required. insure rough dimensions are proper, plumb and square. For whirlpools, access to pump/motor may be made through access opening in apron panel. The following procedure must be used for all installations: leveling support stringer should be as indicated. this bath is not self-supporting and must be supported along it's entire bottom. Support with mortar or grout. Position bathtub/whirlpool within the recess, check level, front to back, side to side, and shim as necessary. To secure the tub to wood studs use drywall screws w/washers or roofing nails immediately above the flange of the tub. To secure the tub to steel studs use 4" drywall screws and flatwashers.

See page 2 for complete installation information.

Caution: Take extra care when driving nails or screws to avoid damaging the tub. The tile or similar finished floor will be butted against the bottom of the tub apron, also holding the tub in place.

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

© American Standard Inc. 2004