INSTALLATION INSTRUCTIONS

THANK YOU...

for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate, peel-out protective film and
inspect your new bath for any shipping damage. If
such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath
from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit
and check for leaks.
If a whirlpool, do not make modifications to the whirlpool
system or remove pump from factory mounting. This
could adversely affect the safety and performance of the
whirlpool and void the warranty. Do not handle or move
the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided
with the bath and must be ordered separately. Framing
and enclosing materials are provided by others. Check
for availability of optional American Standard wall tiling
bead (required for recess installations).
Protect all finished surfaces of the whirlpool during
construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping har-
ness at any time.
NOTE: Deck-mounted fittings are not recommended.
752445-100 Rev. E © American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS

COLONY™ 5' WHIRLPOOL/BATHING POOL

List of Optional Components (not included):
• Tile Bead Kit 751755-100*
• Apron Kit*
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 2 x 3 or 2 x 4
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
60 x 32-3/4 x 19-3/4 In.(1524 x832 x 502mm)
95 Lbs. (43 Kg.)
604 Lbs. (275 Kg.)
61 Gal. (230 L.)
42 Gal. (159 L.)
20 x 39 In. (508 x 991mm)
27-1/2 x 56 In.(699 x 1422mm)
14-1/4 In. (362mm)
44 Lbs./Sq. Ft. (213 Kgs/Sq. m.)
15.6
29.6
GENERAL SPECIFICATIONS FOR 2675 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.1 HP, 9.9 AMPS, 120V.PUMP
464 mm
(18-1/4)
38 mm
(1-1/2)
502 mm
(19-3/4)
1-1/2 O.D.TAILPIECE
BATH
SUPPORT
MATERIAL
LEVELING STRINGER
NOT FOR SUPPORT
ROUGH
FLOOR
1524 mm
(60)
832 mm
(32-3/4)
OUTLINE OF CUTOUT
1486 mm x 794 mm
(58-1/2 X 31-1/4 )
416 mm
(16-3/8)
216 mm
(8-1/2)
305 mm
(12)
38 mm
(1-1/2)
(6) JETS
79 mm
(3-1/8)
CUTOUT IN FLOOR FOR DRAIN
PUMP
FINISHED
WALL
305 mm
(12)
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
1651 & 1981mm
(65 & 78) C/L OF
OVERFLOW
102 mm
(4)
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
70 mm
(2-3/4) 117 mm
(4-5/8)
1-1/2 N.P.T.M.
THREADS
19 mm
(3/4)
229 mm
(9)
C/L OF
SUPPLIES
SEE FITTING
SPECS FOR
DIMENSIONS
(1) AIR VALVE
ON/OFF
SWITCH
PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS

2675 SERIES