Installation (for qualified installers only) | 19 |
Vent Requirements
•The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or
•In addition to the requirements listed here, follow the requirements provided with the vent.
•A firestop is required whenever the vent penetrates a floor or ceiling (or passes through horizontal framing members). A thimble is required whenever the vent passes through a wall (or horizontal framing members).
•Venting installation instructions may be found at www.duravent.com. Keep the vent instructions, along with this manual, with the appliance for future reference.
Approved Vent
•This fireplace may only use the following vent components
|
| Simpson Part # | Travis Part # |
6” Length | 98900024 | ||
12” Length | 98900023 | ||
24” Length | 98900022 | ||
36” Length | 98900021 | ||
48” Length | 98900020 | ||
4” to 8” Adjustable Length (Slip Connector) | 98900025 | ||
45° | Elbow | 98900026 | |
90° | Elbow | 98900027 | |
Wall Thimble | 98900030 | ||
Fire Stop | 98900029 | ||
Elbow Strap | 98900028 | ||
Wall Strap | 98900031 | ||
Adjustable Roof Flashing (0/12 to 6/12) | 98900035 | ||
Adjustable Roof Flashing (7/12 to 12/12) | 98900036 | ||
Storm Collar | 98900032 | ||
Vinyl Siding | 98900037 | ||
Horizontal Termination | 98900033 | ||
Vertical Termination | 98900034 |
Altitude Considerations
•This heater has been tested at altitudes ranging from sea level to 6,000 feet. In this testing we have found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.
•Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter.
Vent Installation
•Slide the vent sections together and turn 1/4 turn until the sections lock in place.
• Screws are not required to secure the vent. However, three screws may be used to secure vent sections together if desired.
•High temperature sealant is recommended at the appliance starter section connection (use
• If disassembly is required, at time of
•Horizontal sections require a 1/4" rise every 12" of travel
•Horizontal sections require