14

Installation (for qualified installers only)

Required Electrical Connection

Make sure power to the heater has been turned off prior to installation (disable the breaker).

Do not connect 110-120 VAC to the gas control valve or the on/off circuit on this fireplace.

This fireplace utilizes 110 VAC to power the receiver module and intermittent pilot system.

The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified installer and must meet all local codes. The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987).

Make sure the household breaker is shut off prior to working on any electrical lines.

The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987)

The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)

Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Attach an electrical line to the receptacle inside the control box (see the illustration below). Make sure to connect the ground wire to the grounding tab on the receptacle (this grounds the fireplace).

Control Box

Cover Plate

Romex Connector

Grounded 110V

Power Supply

Attach the electrical line,

including the grounding wire,

to this receptacle.

© Travis Industries

4090102

100-01212_000

Page 14
Image 14
FireplaceXtrordinair 36CF installation manual Required Electrical Connection