FireplaceXtrordinair 36CF Fireplace Placement Requirements, Clearances, Raised Fireplaces

Models: 36CF

1 48
Download 48 pages 25.16 Kb
Page 10
Image 10
Fireplace Placement Requirements

10

Installation (for qualified installers only)

Fireplace Placement Requirements

Fireplace must be placed in a room with a minimum 96” ceiling.

Fireplace must be placed directly on the sub-floor or wood platform (not on linoleum or carpet).

Fireplace must be installed on a level surface capable of supporting the fireplace and vent.

This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance produces when determining a location.

Clearances

When installed, walls that protrude to the sides of the fireplace must be a minimum 12” from the glass frame (tile stop).

Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies.

Fireplace must be placed so the vents below and above the glass do not become blocked.

Raised Fireplaces

The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace and vent.

Minimum 78” Fireplace

Enclosure Height.

Platform

Optional Raised Hearth (see “Hearth Requirements” for details)

Figure 4

© Travis Industries

4090102

100-01212_000

Page 10
Image 10
FireplaceXtrordinair 36CF installation manual Fireplace Placement Requirements, Clearances, Raised Fireplaces