FireplaceXtrordinair 36CF installation manual Orifice Table, Center Burner, Side Burner

Models: 36CF

1 48
Download 48 pages 25.16 Kb
Page 45
Image 45
ORIFICE TABLE

Finalizing the Installation (for qualified installers only)

45

7The manifolds that secure the three orifices are visible at this point. Detach the air shutter stopper on the mixing tube brackets to gain full access to the orifices (2 screws hold them in place).

8Remove the NG orifices and replace with the LP orifices. See the table below for correct orifice selection (each orifice is stamped for identification).

NOTE: The LP orifice kit only includes two #56 orifices (these install on the side burners). For the center burner, remove one of the side burner orifices (# 52 - shipped on the fireplace for NG configuration) and place it on the center manifold.

ORIFICE TABLE

Center Burner

Side Burner (2)

 

 

 

NG

#32

#52

 

 

 

LP

#52

#56

 

 

 

9Switch the pilot hood to the “LP” size following the directions below.

Un-screw the pilot

Slide this silver tab out.

When in the LP position a hole

Tighten the pilot hood

 

will appear near one of the tabs.

until it is fully secure.

hood 1/4 turn.

 

 

7/16"Wrench

 

 

Figure 26

NOTE: The sliding portion of the pilot orifice may be positioned differently. Instead of pulling it towards you, you may push it away. Either way – when the hole appears near the tab, the orifice is in the LP position.

10 Remove the cover over the gas control valve.

© Travis Industries

4090102

100-01212_000

Page 45
Image 45
FireplaceXtrordinair 36CF installation manual Orifice Table, Center Burner, Side Burner