32

Installation (for qualified installers only)

Hearth Requirements – Recessed Hearth

A hearth is not required if the fireplace is raised 6” above the flooring surface. NOTE: Make sure to accommodate the flooring surface - this distance must be measured from the top of carpeting or other flooring material.

WARNING:

We recommend a hearth to protect the flooring surface from discoloration or other negative impact from the heater, especially if it is near the minimum raised height.

Min. 6”

Side View

Minimum 6” to top of flooring surface (carpet, etc.)

Carpet

Fireplace

 

 

1”

Cement Board

 

 

Plywood (OSB, etc.)

NOTE: When building a raised fireplace, consider the facing

 

 

 

material below the fireplace. If using tile, you may wish to

Framing

 

make the platform a suitable height for un-cut tile. For

Sub-Floor

 

example, if using 12” tile, make the platform 11” tall (10-1/2”

 

section of framing + 1/2” plywood).

 

 

Figure 21

© Travis Industries

4090102

100-01212_000

Page 32
Image 32
FireplaceXtrordinair 36CF installation manual Hearth Requirements Recessed Hearth