Installation (for qualified installers only)

31

Hearth Requirements

NOTE: Whenever using a hearth over 1” thick, the fireplace will need to be raised.

Flush Hearth

Non-Combustible

Min. 3/4”

Max 1”

Min. 64” (on ST, Pier will vary)

Min.10”

Side View

Fireplace

Tile

1”

Cement Board

Hearth Material over 1” Thick (granite, concrete, etc.)

Fireplace

1”

Plywood (OSB, etc.)

Framing

Sub-Floor

NOTE: Do not build a hearth more than the 1” maximum above the base of the fireplace (it must fit under the glass frame).

Fireplace

Marble

1”

Figure 20

© Travis Industries

4090102

100-01212_000

Page 31
Image 31
FireplaceXtrordinair 36CF installation manual Hearth Requirements, Flush Hearth