ELLISSE ELITE™ 6’ x 48”
WHIRLPOOLS BY AMERICAN STANDARD
HIGH GLOSS ACRYLIC
305mm
(12)
1219mm
(48)
| 1829mm |
| |
| (72) |
| |
| ON/OFF SWITCH |
| |
927mm | OUTLINE OF CUTOUT |
| |
102mm | |||
1791 X 1181 | |||
| |||
| (4) | ||
| |||
|
| ||
|
| C/L OF | |
|
| DRAIN | |
| 229mm x 356mm |
| |
| (9 x 14) FLOOR | PUMP | |
| CUTOUT | ||
|
|
RECOMMENDED FITTING LOCATION 64X279mm
51mm
(2)
INTEGRAL
FEET
SUPPORT
GRAB BAR
FITTING AREA | OPTIONAL | PROVIDE ACCESS | |
TO PUMP FOR SERVICE | |||
| |||
| DECK FITTING | ||
| ON ALL INSTALLATIONS | ||
| AREA | ||
|
|
| LEVELING STRINGER | |||
| HEATER | (NOT FOR SUPPORT) | ||
| REMOVABLE | C/L OF | ||
| BLANK |
| ||
|
| OVERFLOW | ||
|
|
| ||
|
| 105mm | 546mm | |
|
| |||
|
| |||
|
|
| ||
|
| ROUGH | 495mm | |
|
| FLOOR | ||
|
|
| ||
64mm | 121mm | |||
| ||||
|
|
GENERAL SPECIFICATIONS FOR 2711E WHIRLPOOL
INSTALLED SIZE | 72 x 48 x | ||||||||
WEIGHT |
|
| 148 Lbs. (67 Kg.) | ||||||
WEIGHT w/WATER |
|
| 965 Lbs. (434 Kg.) | ||||||
GAL. TO OVERFLOW |
|
| 95 Gal. (360 L) | ||||||
WHIRLPOOL MIN. OPERATING VOL. |
| 74 Gal. (280 L) | |||||||
BATHING WELL AT SUMP |
|
| 43 x 28 In. (1092 x 711mm) | ||||||
BATHING WELL AT RIM |
|
| 68 x 38 In. (1727 x 965mm) | ||||||
WATER DEPTH TO OVERFLOW |
| ||||||||
FLOOR LOADING |
|
| 40 Lbs./Sq.Ft. (195 Kgs./Sq.m) | ||||||
(PROJECTED AREA) |
|
|
|
|
| ||||
PTS. |
|
|
|
| 41.7 | ||||
CUBE (FT3) |
|
|
| 81.9 | |||||
|
|
| |||||||
|
|
| WHIRLPOOL ELECTRICAL SPECIFICATIONS | ||||||
PUMP |
|
|
|
| 2.1 HP, 14.4 AMPS ,120V. |
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUMP OF BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.
■REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION. OPTIONAL GRAB BAR KIT No.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY. PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
●IF INSTALLING A
SUPPLY PIPING NOT INCLUDED.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1.These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.