American Standard 2722.102 RHO, 2722.102 LHO Illustration, Rough-Ininformation

Models: 2722.102 LHO 2722.102 RHO

1 5
Download 5 pages 38.06 Kb
Page 2
Image 2
ROUGH-IN INFORMATION:

ROUGH-IN INFORMATION:

GENERAL SPECIFICATIONS FOR 2722 BATHING POOL

INSTALLED SIZE

 

 

 

 

 

 

 

 

 

 

60 x 32 x 17 In.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1524 x 813 x 432mm)

WEIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

60 Lbs. (27 Kg)

WEIGHT w/WATER

 

 

 

 

 

 

 

393 Lbs.(179 Kg)

 

 

 

 

 

 

 

GAL. TO OVERFLOW

 

 

 

 

 

 

 

 

 

40 Gal. (151 L)

 

 

 

 

 

 

 

 

 

BATHING WELL AT SUMP

 

 

 

22 x 44 In. (559 x 1118mm)

 

 

 

BATHING WELL AT RIM

 

 

 

 

25.5 X 53 In.(648 x 1346mm)

 

 

 

 

WATER DEPTH TO OVERFLOW

 

 

 

 

 

10 In. (254mm)

 

 

 

 

 

FLOOR LOADING

 

 

29 Lbs./Sq.Ft. (195 Kgs/Sq.m)

 

 

(PROJECTED AREA)

 

 

 

 

 

 

 

 

 

 

PTS.

 

 

 

 

 

15.3

CUBE (FT3)

 

 

 

 

 

27

 

 

 

 

 

 

60"

 

 

9-3/8"

(1524mm)

 

 

(238mm)

FINISHED

70mm

 

3/4"

(2-3/4)

 

(19mm)

WALL

 

 

 

15-1/8"

 

 

 

(385mm)

 

 

 

 

229mm x 305mm

 

 

 

(9 x 12)

 

 

 

FLOOR

 

 

 

CUTOUT

 

 

32"

 

 

 

(813mm)

 

 

 

25mm

4-1/2"

 

 

(1) C/L OF

(114mm)

 

 

DRAIN

 

 

 

 

 

FINISHED

 

 

WALL

 

TOP OF

3-1/2"

 

 

DECK

(89mm)

 

 

1"

 

 

 

(25mm)

 

SEE

16-3/4"

17"

 

 

NOTE

 

(425mm)

(432mm)

 

 

 

 

2"

 

 

 

 

 

 

(51mm)

 

 

 

 

ROUGH

4-5/8"

 

 

FLOOR

1-1/2 N.P.T. THREADS

(117mm)

1-1/2 O.D. TAILPIECE

 

 

 

BATH SUPPORT

 

 

 

MATERIAL

 

 

 

1 INSTALLATION AND FRAMING INSTRUCTIONS:

A.) Locate studs as required. Ensure roughing-in dimensions are proper, plumb, and square. It is strongly recommended that an additional opening be provided for access to the drain components.

Illustration 1

Illustration 1 Each alcove stud must be plumb and square.

B.) As shown in ILL. 2, mark the position of the underside of the deck by tracing a line onto the studs at the height indicated, using a level or other suitable straight edge.

C.) With the top of the stringer touching the traced line, attach the stringer to the studs.

Illustration 2

 

 

 

 

16-3/4

 

 

 

 

(425mm)

 

 

0

 

 

 

3

)

 

 

 

 

m

 

 

 

m

 

 

2

 

 

6

 

 

 

(7

 

 

 

D.) Install drain components to the bath following the manufacturer's instructions. See the roughing-in drawing for suggested opening size and location dimensions.

2

754049-100 Rev. G

Page 2
Image 2
American Standard 2722.102 RHO, 2722.102 LHO installation instructions Illustration, Rough-Ininformation