1 INSTALL FAUCET

CAUTION

Turn off hot and cold water supplies before beginning.

Place faucet in position on sink.

Assemble and tighten LOCKNUTS from underside of SINK.

Connect the HOT water supply to the left SHANK and the COLD water supply to the right SHANK using appropriate connectors and sealant (not supplied), and COUPLING NUTS.

BODY

SHANK

PUTTY

PLATE

SINK

COLD

LOCKNUT

HOT

NOT SUPPLIED

COUPLING NUT

2 TEST INSTALLED FAUCET

Remove AERATOR.

With handles in OFF position, turn on water supplies and check all connections for leaks.

Operate both handles to flush water lines thoroughly.

Turn handles into OFF position and replace AERATOR.

3 SERVICE

STOP

WASHER

To change direction of handle rotation, proceed as follows:

Turn valve to OFF position.

Pull out INDEX CAP and remove

HANDLE SCREW.

Pull off HANDLE BASE and remove

ADAPTER.

Remove SPRING CLIP.

Lift STOP WASHER, turn 90$ and replace.

Replace SPRING CLIP.

Reinstall HANDLE.

90$

SPRING

CLIP

Handle alignment.

Check alignment, if not satisfactory aligned;

Push out ADAPTER carefully.

Turn ADAPTER either 45˚ or 90˚ so that male square on ADAPTER catches different female square in HANDLE BASE.

Assemble and tighten

MOUNTING SCREW.

Push INDEX CAP in top of

HANDLE.

FEMALE SQUARE IN HANDLE BASE

HANDLE

ADAPTER

SQUARE

VALVE

STEM

AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and rinse clean.

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90$.

4 EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

.        3 & 7    

Page 2
Image 2
American Standard 2770.702 Series, 2770.732 Series Install Faucet, Cold, Hot, Test Installed Faucet, Service