CADET™ 6' x 42"

HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS

2774.XXXW SERIES

WHIRLPOOL/BATHING POOL

INSTALLATION INSTRUCTIONS

 

 

 

 

 

 

 

 

 

PROVIDE ACCESS TO PUMP FOR

 

 

 

 

 

 

 

 

 

SERVICING ON ALL INSTALLATIONS

 

 

 

 

 

 

 

 

 

1829 mm

 

 

 

 

 

 

 

 

 

305 mm

(72)

 

 

 

 

 

 

 

 

 

RECOMMENDED FITTING LOCATION

 

 

229mm

 

 

 

(12)

 

 

 

 

 

 

 

 

 

 

64 X 330mm (2-1/2 x 13")

 

 

(9)

 

 

 

 

 

 

 

 

 

 

19 mm

 

 

 

 

 

FOR PIER OR ISLAND

 

 

 

(3/4)

 

 

 

 

 

 

 

INSTALLATIONS ONLY

 

 

 

 

 

 

 

 

 

THANK YOU...

for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The

SEE FITTING SPECS FOR DIMENSIONS

FINISHED WALL

whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the

 

 

 

 

 

 

ON/OFF

 

 

 

 

 

 

SWITCH

 

 

229 mm

 

 

 

 

 

(9)

 

 

 

 

1067mm

 

 

 

 

PUMP

 

(42)

 

CUTOUT IN FLOOR

 

 

533mm

 

 

 

 

 

FOR DRAIN

 

 

 

(21)

 

 

 

 

 

 

 

 

 

 

C/L OF

57mm

 

 

 

(2) AIR VALVES

OUTLINE OF CUTOUT

SUPPLIES

(2-1/4)

 

(8) JETS

ALT. FITTING

1791mm x 1029mm

 

 

 

 

(70-1/2 X 40-1/2)

 

C/L OF DRAIN

 

LOCATION #1

 

 

 

 

 

 

C/L OF

 

 

 

 

 

 

 

 

 

 

 

 

SHOWER ARM

 

OPTIONAL TO

 

 

 

 

 

 

FINISHED FLOOR

 

 

 

 

C/L OF

 

USUALLY BETWEEN

 

 

 

 

1651 & 1981mm

 

 

 

 

VALVES

SAFE-T-HEATER

(65 & 78)

C/L OF

 

 

 

 

 

 

 

 

REMOVABLE

 

 

 

 

C/L OF

 

OVERFLOW

 

305mm

 

BLANK

 

38mm

(12)

 

SPOUT

 

 

(1-1/2)

 

 

 

 

102mm

 

 

LEVELING

 

89mm

 

 

 

 

 

 

 

STRINGER

 

(3-1/2)

 

(4)

 

 

 

 

 

 

 

NOT FOR

 

 

 

 

 

 

 

 

 

 

 

 

SUPPORT

 

502mm

 

 

 

 

 

 

(19-3/4)

 

 

 

 

464 mm

 

ROUGH

 

 

 

 

(18-1/4)

 

 

 

 

 

 

 

FLOOR

 

 

 

 

 

 

INTEGRAL

 

1-1/2 N.P.T.M.

 

 

 

 

SUPPORT

 

THREADS

 

70 mm

 

 

FEET

1-1/2 O.D.TAILPIECE

(2-3/4)

 

 

 

117 mm

 

 

 

 

 

 

 

 

 

 

(4-5/8)

GENERAL SPECIFICATIONS FOR 2774 WHIRLPOOL

INSTALLED SIZE

 

 

 

72 x 42 x 19-3/4 In.

 

 

 

(1829mm x 1067 mm x 502mm)

WEIGHT

 

 

 

 

137 Lbs. (62 Kg.)

WEIGHT w/WATER

 

 

 

821 Lbs. (372 Kg.)

GAL. TO OVERFLOW

 

 

 

82 Gal. (310 L.)

MIn. OPERATING GAL.

 

 

 

66 Gal. (256 L.)

BATHING WELL AT SUMP

50 x 27 In. (1270 mm x 686 mm)

BATHING WELL AT RIM

 

 

65 x 33 In. (1651 x 838mm)

WATER DEPTH TO OVERFLOW

 

13 In. (330 mm)

FLOOR LOADING

 

42 Lbs./Sq. Ft. (203 Kgs/Sq. m.)

(PROJECTED AREA)

 

 

 

 

 

PTS.

 

 

 

 

 

27.8

CUBE (FT3)

 

 

 

 

 

55.5

WHIRLPOOL ELECTRICAL SPECIFICATIONS

PUMP

 

 

 

 

2.1 HP, 14.4 AMPS, 120V.

installation are your selected fittings and electrical connections for a whirlpool.

To insure maximum performance and pleasure from this product, please follow the instructions and cautions.

List of Optional Components (not included):

Safe-T-Heater 9075.120*

Tile Bead Kit 751755-100*

Apron Kit*

* see your American Standard Distributor

List of Required Components (not included):

Drain* 1583.470

• Bath Filler*

* see your American Standard Distributor

List of Required Tools and Supplies:

Tools

Supplies

Level

Nails

Tape Measure

Putty

Pipe Wrench

Caulking (waterproof)

Slip Joint Pliers

1 x 3 or 2 x 2

Screw Driver

 

Stringers

Standard

Drop Cloth

 

Woodworking Tools

20 amp GFI

Personal Safety

 

Outlet

 

Equipment

Cement, Plaster,

Caulking Gun

 

Grout

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.

After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.

WARNING! Do not lift whirlpool by the piping harness at any time.

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

© American Standard Inc. 2003

752502-100 REV. HAll product names listed herein are trademarks of American Standard Inc. unless otherwise noted.