CADET™ 5 x 32
INTEGRAL APRON WITH REMOVABLE ACCESS PANEL HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS
2776.XXXW SERIES
WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
|
|
|
|
|
| |
| 12 |
|
| (1521mm) |
| |
(305mm) |
|
|
| WATER |
| |
|
|
| RETENTION | |||
|
|
|
| |||
(197mm) |
|
|
|
| ||
|
|
|
| FLANGE |
| |
3/4 |
|
|
|
|
| |
|
|
|
| (3 SIDES) |
| |
(19mm) |
|
|
|
|
| |
|
|
|
|
|
| |
FINISHED |
|
|
|
|
|
|
SEE FITTING WALL |
|
|
|
|
|
|
SPECS FOR |
|
|
|
|
| |
DIMENSIONS |
|
|
|
|
| |
|
|
|
|
| (375mm) | |
|
|
|
|
|
| |
|
|
| 9 |
|
|
|
| (229 mm) |
|
| |||
32 |
|
|
|
|
| ON/OFF |
|
|
|
| PUMP | SWITCH | |
(813mm) |
| CUTOUT IN FLOOR | ||||
|
| |||||
|
|
|
| |||
|
| FOR DRAIN |
|
| ||
C/L OF |
|
|
| (2) AIR VALVES | ACCESS TO PUMP/MOTOR | |
SUPPLIES | (60mm) |
|
| (8) JETS |
| THROUGH REMOVABLE |
|
|
|
|
|
| FRONT ACCESS PANEL |
| C/L OF DRAIN |
| C/L OF |
| ||
|
|
|
|
| SHOWER ARM | |
|
|
|
|
| FINISHED |
|
OPTIONAL TO |
|
|
|
| WALL |
|
FINISHED FLOOR | 7/8 WATER |
|
| C/L OF |
| |
USUALLY BETWEEN |
|
|
| |||
65 & 78 | RETENTION |
|
| VALVES |
| |
(1651 & 1981mm) | FLANGE |
|
|
|
| |
| (3 SIDES) |
| 12 | C/L OF |
| |
| C/L OF |
|
|
| ||
|
| (305mm) OPT. | SPOUT |
| ||
| OVERFLOW |
|
| |||
|
|
| 4 |
|
| |
|
|
| ■ LEVELING STRINGER | |||
|
|
| (102 mm) | |||
| (70mm) |
|
| NOT FOR SUPPORT | ||
|
|
|
| |||
TOP OF |
|
|
|
|
| UNDERSIDE |
DECK | 20 |
|
|
|
| OF DECK |
|
|
|
|
|
| |
| (508mm) |
|
|
|
| |
| ROUGH |
|
|
|
| (502mm) |
|
|
|
|
|
| |
| FLOOR |
|
|
|
|
|
| BATH |
|
|
|
| |
| SUPPORT |
|
| THREADS |
| |
| MATERIAL | (70mm) |
| |||
|
| |||||
|
|
|
|
| ||
|
|
|
|
| (117mm) | |
GENERAL SPECIFICATIONS FOR 2776 WHIRLPOOL |
| |||||
INSTALLED SIZE |
|
| ||||
WEIGHT |
|
|
|
| 115 Lbs. (52 Kg.) | |
WEIGHT w/WATER |
|
|
| 574 Lbs. (258 Kg.) | ||
GAL. TO OVERFLOW |
|
|
| 55 Gal. (208 L.) | ||
WHIRLPOOL MIN. OPERATING VOL. | 45 Gal. (171 L.) | |||||
BATHING WELL AT SUMP |
|
|
| 20 x 40 (508 x 1016mm) | ||
BATHING WELL AT RIM |
|
| 26 x | |||
WATER DEPTH TO OVERFLOW | ||||||
FLOOR LOADING |
|
| 43 Lbs./Sq.Ft. (208 Kgs./Sq.m) | |||
(PROJECTED AREA) |
|
|
|
|
| |
PTS. |
|
|
|
|
| 20.8 |
CUBE (FT3) |
|
|
|
|
| 35.3 |
WHIRLPOOL ELECTRICAL SPECIFICATIONS |
| |||||
SYSTEM I PUMP |
|
|
| 1.1 HP, 9.9 AMPS,120V. |
GENERAL INSTALLATION INFORMATION
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Required Components (not included):
• Drain 1583.470* • Bath Filler* * see your American Standard Distributor
List of Required Tools and Supplies:
Tools | Supplies | ||
• | Level | • | Nails |
• | Tape Measure | • | Putty |
• | Pipe Wrench | • | Caulking (waterproof) |
• | Slip Joint Pliers | • | 1 x 3 or 2 x 2 |
• | Screw Driver |
| Stringers |
• | Standard | • | Drop Cloth |
| Woodworking Tools | • | 15 amp GFI |
• | Personal Safety |
| Outlet |
| Equipment | • | Cement, Plaster, |
• | Caulking Gun |
| Grout |
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. Before installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others.
BATH MAY ONLY BE INSTALLED IN A RECESS TYPE INSTALLATION. | IMPORTANT: |
| Water test unit before installation and enclosure! |
LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR WHIRLPOOLS, ACCESS TO PUMP/MOTOR MAY BE MADE THROUGH ACCESS OPENING IN APRON PANEL. THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: LEVELING SUPPORT STRINGER SHOULD BE AS INDICATED. THIS BATH IS NOT
POSITION BATHTUB/WHIRLPOOL WITHIN THE RECESS, CHECK LEVEL, FRONT TO BACK, SIDE TO SIDE, AND SHIM AS NECESSARY.
TO SECURE THE TUB TO WOOD STUDS USE DRYWALL SCREWS W/WASHERS OR ROOFING NAILS IMMEDIATELY ABOVE THE FLANGE OF THE TUB. TO SECURE THE TUB TO STEEL STUDS USE 4" DRYWALL SCREWS AND FLATWASHERS.
SEE PAGE 2 FOR COMPLETE INSTALLATION INFORMATION.
CAUTION: TAKE EXTRA CARE WHEN DRIVING NAILS OR SCREWS TO AVOID DAMAGING THE TUB.
THE TILE OR SIMILAR FINISHED FLOOR WILL BE BUTTED AGAINST THE BOTTOM OF THE TUB APRON, ALSO HOLDING THE TUB IN PLACE.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
© American Standard Inc. 2003