American Standard 2805EC WILLIAMSBURG ELITE 5’ x 42”, Whirlpools By American Standard, CUBE FT3

Models: 2805EC

1 2
Download 2 pages 52.29 Kb
Page 2
Image 2
GENERAL SPECIFICATIONS FOR 2805E WHIRLPOOL

WILLIAMSBURG ELITE™ 5’ x 42”

WHIRLPOOLS BY AMERICAN STANDARD

HIGH GLOSS ACRYLIC

 

1524mm

 

 

(60)

 

762mm

INTEGRAL

 

FITTING DECK

152mm

(30)

 

 

(6)

 

 

305mm

 

C/L OF

(12)

 

 

 

DRAIN

 

 

PUMP

1067mm

178mm x 381mm

 

(7 x 15)

 

(42)

 

FLOOR

 

 

PROVIDE ACCESS

 

CUTOUT

 

 

TO PUMP FOR

 

 

SERVICE ON ALL

 

 

INSTALLATIONS

 

 

ON/OFF

 

 

SWITCH

 

 

19mm

 

 

(3/4)

 

OUTLINE OF CUTOUT

 

1486mm x 1029mm

 

 

(58-1/2 x 40-1/2)

 

IN-LINE HEATER

51mm(2) REMOVABLE BLANK

546mm (21-1/2)

495mm (19-1/2)

ROUGHCUBE (FT3) INTEGRAL

FLOOR FEET

LEVELING STRINGER

NOT FOR SUPPORT

133mm (5-1/4)

WHIRLPOOL ELECTRICAL SPECIFICATIONSC/L OF

OVERFLOW

64mm (2-1/2)

1-1/2 N.P.T.NOTES:

THREADS

1-1/2 O.D.

TAILPIECE121mm (4-3/4)

GENERAL SPECIFICATIONS FOR 2805E WHIRLPOOL

INSTALLED SIZE

60 x 42 x 21-1/2 In. (1524 x 1067 x 546mm)

WEIGHT

 

 

 

130 Lbs. (59 Kg.)

WEIGHT w/WATER

 

 

 

689 Lbs. (310 Kg.)

GAL. TO OVERFLOW

 

 

 

64 Gal. (243 L)

WHIRLPOOL MIN. OPERATING VOL.

 

 

52 Gal. (197 L)

BATHING WELL AT SUMP

 

 

 

43 x 22 In. (1092 x 559mm)

BATHING WELL AT RIM

 

55 x 35-1/2 In. (1397 x 902mm)

WATER DEPTH TO OVERFLOW

 

 

14 In. (356mm)

FLOOR LOADING

 

 

 

39 Lbs./Sq.Ft. (191 Kgs./Sq.m)

 

 

 

(PROJECTED AREA)

 

 

 

 

 

 

PTS.

 

 

 

 

27.8

 

 

 

 

CUBE (FT3)

 

 

 

47.4

 

 

 

 

 

 

WHIRLPOOL ELECTRICAL SPECIFICATIONS

PUMP

 

 

 

 

 

1.6 HP, 9.7 AMPS ,120V.

NOTES:

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUMP OF BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.

OPTIONAL 3- WALL TILING BEAD KIT No. TILE-BEAD AND APRON WBURG5-APRON MUST BE ORDERED SEPARATELY.

FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.

IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING SYSTEM PIPING, DRAIN OVERFLOW. MOUNTING HOLES DRILLED BY INSTALLER.

SUPPLY PIPING NOT INCLUDED.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1.These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.