American Standard 2806EC WILLIAMSBURG ELITE 6 FT, Whirlpools By American Standard, CUBE FT3

Models: 2806EC

1 2
Download 2 pages 61.67 Kb
Page 2
Image 2
GENERAL SPECIFICATIONS FOR 2806E WHIRLPOOL

WILLIAMSBURG ELITE™ 6 FT

WHIRLPOOLS BY AMERICAN STANDARD

HIGH GLOSS ACRYLIC

1829mm

279mm

 

(72)

(11)

 

 

 

ON/OFF

 

 

SWITCH

 

457mm

229 x 330mm

PUMP

(18)

(9 X 13)

 

 

 

 

FLOOR

 

 

CUTOUT

 

914mm

(36)

INTEGRAL CUBE (FT3)

FITTING DECK

140mm

 

OUTLINE OF

 

PROVIDE ACCESS

(5-1/2)

C/L OF

 

CUTOUT

TO PUMP FOR SERVICE

 

 

DRAIN

 

 

ON ALL INSTALLATIONS

 

OVERFLOW

 

 

 

 

 

C/L OF

108mm

LEVELING STRINGER

OVERFLOW

(4-1/4)

(NOT FOR SUPPORT)

 

 

 

 

IN-LINE HEATER

 

 

 

 

REMOVABLE

 

51mm

 

 

BLANK

 

 

 

546mm

INTEGRAL

(2)

 

 

(21-1/2)

FEET

 

 

 

495mm

SUPPORT

 

 

 

 

 

 

(19-1/2)

ROUGH

 

 

 

 

 

FLOOR

 

 

 

 

1-1/2 N.P.T.M. THREADS

 

 

 

 

1-1/2 O.D.TAILPIECE

 

51mm

108mm

 

 

 

(4-1/4)

 

 

 

(2)

 

GENERAL SPECIFICATIONS FOR 2806E WHIRLPOOL

INSTALLED SIZE

72 x 36 x 21-1/2 In. (1829 x 914 x 546mm)

WEIGHT

 

135 Lbs. (61 Kg.)

WEIGHT w/WATER

 

744 Lbs. (338 Kg.)

GAL. TO OVERFLOW

 

73 Gal. (276 L)

WHIRLPOOL MIN. OPERATING VOL.

44 Gal. (167 L)

BATHING WELL AT SUMP

 

45 x 24 In. (1143 x 610mm)

BATHING WELL AT RIM

 

60 x 30 In. (1524 x 762 mm)

WATER DEPTH TO OVERFLOW

 

14-1/2 In. (368mm)

FLOOR LOADING

 

 

41 Lbs./Sq.Ft. (198 Kgs./Sq.m)

(PROJECTED AREA)

 

 

 

 

PTS.

 

 

 

 

25.6

CUBE (FT3)

 

 

 

49.4

 

 

 

 

WHIRLPOOL ELECTRICAL SPECIFICATIONS

PUMP

 

2.1 HP, 14.4 AMPS ,120V.

NOTES:

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUMP OF BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.

CUTOUT TEMPLATE PROVIDED IN SHIPPING BOX. MAY BE REQUESTED SEPARATELY. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.

IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING SYSTEM PIPING, DRAIN OVERFLOW, AND APRON INSTALLATION. MOUNTING HOLES DRILLED BY INSTALLER.

SUPPLY PIPING NOT INCLUDED.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1.These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.

© 2003 American Standard Inc.

Page 2
Image 2
American Standard 2806EC WILLIAMSBURG ELITE 6 FT, Whirlpools By American Standard, CUBE FT3, American Standard Inc, Notes