9 TEST INSTALLED FITTING

9 TEST INSTALLED FITTING

4

With HANDLES (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3).

1

Operate both HANDLES (1) to flush water lines thoroughly.

Replace AERATOR (3).

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB (4) and fill lavatory with water. Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.

1

Manual background 3

Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. Tighten Manual background

if necessary.

5

WASTE

OUTLET

 

2

 

2

 

 

“P” TRAP

10

INSTALLATION OF OPTIONAL METAL LEVER HANDLES

 

7

(Supplied with Faucet)

 

5

Thread PORCELIAN LEVER HANDLE (2) counter-clockwise

2

4

 

 

and remove INDEX BUTTON with MOUNTING ROD ASSEMBLY (1),

 

3

HANDLE COLLAR (4) and O-RING (5).

 

 

 

Insert MOUNTING ROD ASSEMBLY (1) into METAL HANDLE (3),

1

 

HANDLE COLLAR (4) and O-RING (5).

 

Thread HANDLE ASSEMBLY (6) into ball of HANDLE BASE (7).

 

 

Apply pressure to the MOUNTING ROD ASSEMBLY (1)

 

 

while turning the HANDLE COLLAR (4), in order to tighten

 

6

firmly.

 

 

11 SERVICE

90

 

STOP

 

 

WASHER

 

To change direction of handle rotation,

 

proceed as follows:

 

 

Turn valve to OFF position.

 

 

Pull out INDEX CAP and remove

 

 

HANDLE SCREW.

 

 

Remove SPRING CLIP.

 

 

Lift STOP WASHER, turn 90˚ and replace.

 

Replace SPRING CLIP.

 

SPRING

Replace ADAPTER, HANDLE, SCREW, and INDEX CAP.

CLIP

AERATOR may accumulate dirt causing distorted and reduced water flow. Remove AERATOR and rinse clean.

If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.

ALIGN HANDLES

Pull out INDEX CAP (1) and remove HANDLE SCREW (2), HANDLE (3) and ADAPTER (4).

Push ADAPTER (4) on VALVE STEM (5). Find correct position of HANDLE (3) by adjusting male teeth on ADAPTER (4) to female teeth on HANDLE (3).

Replace HANDLE SCREW (2) and push in INDEX CAP (1).

1

2

3

4

5

12 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M968423 Rev . 1 . 2