TROUBLESHOOTING GUIDE

 

 

 

 

 

Symptom

Possible Cause

Action

 

 

 

 

 

Display will not

Thermostat is not

Check if the thermostat is mounted and

come on.

being powered.

latched on the wallplate–mount and latch the

 

 

thermostat on the wallplate.

 

 

Check if the circuit breaker is tripped–reset

 

 

the circuit breaker.

 

 

Check if the fuse is blown–replace the fuse.

 

 

Check if the system switch is in the Off

 

 

position–set to Heat or Cool.

 

 

 

Temperature

The upper or lower

Check that the temperature setpoints are

settings will not

temperature limits

within range:

 

change (Example:

were reached.

Heating: 50

°

to 99° F (10 ° to 37° C)

cannot set the

 

Cooling: 50

°

to 99° F (10 ° to 37° C).

heating higher or the

 

 

 

 

cooling lower).

 

 

 

 

 

 

 

 

 

 

 

 

 